Main Sub<br />

code code<br />

5 01 Operation panel display<br />

check (LCD/LED CHK)<br />

02 Fusing lamp, cooling fan<br />

operation check (HT LAMP<br />

CHK)<br />

03 Copy lamp ON check<br />

(C-LAMP CHK)<br />

Contents Details of function/operation<br />

[Function]<br />

<br />

When [ENTER/START] key is pressed, all the LCD's on the operation panel are turned ON (all pixels<br />

ON).<br />

After 5sec of ON, the machine goes into the sub code entry standby mode.<br />

When [MODE SWITCH] key is pressed under the all ON state, the mode is shifted to the individual<br />

ON mode, where the LED's are turned on one by one from the left upper end to the left lower side<br />

then from the right upper side to the right lower side. (All the pixels of LCD are lighted simultaneously.)<br />

After lighting all the LCD's sequentially, all the LCD's are lighted simultaneously. After 5sec from lighting<br />

all the LCD's simultaneously, the machine goes into the sub code entry standby mode. (Cycle of<br />

individual ON mode: ON 300ms, OFF 20ms)<br />

When [C] key is pressed in the LED check mode, the machine goes into the sub code entry standby<br />

mode.<br />

When [START] key is pressed, the machine goes into the key input check mode.<br />

<br />

When the machine goes into the key input check mode, the LCD displays 0.<br />

When any key is pressed after pressing a key on the operation panel, "+1" is added to the value.<br />

Once a key is pressed, it is not recounted.<br />

When [START] key is pressed, counting is made and the machine goes into the LED ON check mode<br />

(LED all ON status) after 3sec.<br />

When [C] key is pressed for the first time, it is counted. When it is pressed for the second time, the<br />

machine goes into the sub code entry mode.<br />

When [CA] key is pressed for the first time, it is counted. When it is pressed for the second time, the<br />

machine goes out from the test command mode.<br />

(Note in the key input check mode)<br />

• Be sure to press [START] key at the last. (If it is pressed on the way, the machine goes into the LED<br />

ON check mode.) (LED all ON status)<br />

• Multi key input is ignored.<br />

[Operation]<br />

<br />

1) Initial display<br />

■■■■■■■■■■■■■■■■■■■■■<br />

■■■■■■■■■■■■■■■■■■■■■<br />

2) When [MODE SWITCH] key is pressed, the machine goes into the individual ON mode.<br />

<br />

1) Initial display 2) [ENTER/START]<br />

05-01 LCD/LED CHK.<br />

[Function]<br />

When [ENTER/START] key is pressed, the fusing lamp repeats ON for 500ms and OFF for 500ms 5<br />

times. During this period, the cooling fan motor rotates.<br />

[Operation]<br />

1) Initial display<br />

05-02 HT LAMP CHK<br />

EXECUTING...<br />

[Function]<br />

When [ENTER/START] key is pressed, the copy lamp turns ON for 5sec.<br />

[Operation]<br />

1) Initial display<br />

05-03 C-LAMP CHK<br />

EXECUTING...<br />

AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 5<br />

0<br />

05-01 LCD/LED CHK.<br />

**

Hooray! Your file is uploaded and ready to be published.