code code<br />

66 03 FAX PWB memory check<br />

(Executable only when the<br />

FAX is installed.)<br />

Contents Details of function/operation<br />

04 Signal send mode (Max.<br />

value) (Executable only<br />

when the FAX is installed.)<br />

[Function]<br />

Use to check the FAX PWB memory.<br />

[Operation]<br />

1) Initial display<br />

SELECT CHECK MEMORY<br />

PRESS ←, →<br />

2) [←/→] or after 2sec<br />

Every time when [→] key is pressed, the second line is changed in the sequence of No. 1 → 2 →<br />

3 → 1.<br />

When [←] key is pressed, the sequence is reversed.<br />

SELECT MEMORY (1-3)<br />

1:DRAM<br />

∗ [CLEAR] key: FAX control is terminated.<br />

3) [ENTER] key<br />

CHECKING MEMORY<br />

4) After completion of check<br />

• When the result is OK<br />

MEMORY CHECK RESULT<br />

OK<br />

• In case of sum check error<br />

MEMORY CHECK RESULT<br />

XXXXXXXX SUM NG<br />

∗ [CLEAR] key: Returns to "1) Initial display".<br />

[Function]<br />

Use to set the signal send mode (Max. value).<br />

Facsimile test command design specifications.<br />

[Operation]<br />

SELECT MEMORY (1-3)<br />

2:SRAM<br />

• In case of address bus check<br />

error<br />

MEMORY CHECK RESULT<br />

XXXXXXXX A-BUS NG<br />

• In case of data check error<br />

MEMORY CHECK RESULT<br />

XXXXXXXX DATA NG<br />

AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 32<br />

SELECT MEMORY (1-3)<br />

3:FLASH<br />

• In case of data bus check<br />

error<br />

MEMORY CHECK RESULT<br />

XXXXXXXX D-BUS NG<br />

• In case of erase check error<br />

MEMORY CHECK RESULT<br />

XXXXXXXX ERASE NG<br />

1 NO SIGNAL 13 7200bps(V34) 25 2400bps(V27ter)<br />

2 33600bps(V34) 14 4800bps(V34) 26 300bps(FLAG)<br />

3 31200bps(V34) 15 2400bps(V34) 27 2<strong>10</strong>0Hz(CED)<br />

4 28800bps(V34) 16 14400bps(V33) 28 1<strong>10</strong>0Hz(CNG)<br />

5 26400bps(V34) 17 12000bps(V33) 29 300bps(V21)<br />

6 24000bps(V34) 18 14400bps(V17) 30 2<strong>10</strong>0Hz(ANSam)<br />

7 21600bps(V34) 19 12000bps(V17) 31 DUMMY RING<br />

8 19200bps(V34) 20 9600bps(V17) 32 NO VOICE ANSWER<br />

9 16800bps(V34) 21 7200bps(V17) 33 NO RING BACK TONE<br />

<strong>10</strong> 14400bps(V34) 22 9600bps(V29) 34 LINE OFF HOOK<br />

11 12000bps(V34) 23 7200bps(V29) 35 LINE ON HOOK<br />

12 9600bps(V34) 24 4800bps(V27ter)<br />

1) Initial display<br />

SELECT OUTPUT SIGNAL<br />

(2 DIGITS) No.___<br />

2) 2-digit (1-35) with [<strong>10</strong>KEY] / [←/→] / 2sec after<br />

Pressing [→] key or [←] key reverses the sequence.<br />

No. (1-35)<br />

1:NO SIGNAL<br />

∗ [CLEAR] key: FAX control is terminated.<br />

3) [ENTER] key<br />

Send after setting<br />

OUTPUTING SIGNAL MAX<br />

PRESS CLEAR TO STOP<br />

∗ [CLEAR] key: Returns to "1) Initial display".<br />

..... No. (1-35)<br />

35:LINE ON HOOK