[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Main Sub<br />
code code<br />
<strong>10</strong> 00 Toner motor operation<br />
(TONER MOTOR)<br />
14 00 Cancel of trouble other than<br />
U2 (TRBL CANC.)<br />
16 00 U2 trouble cancel (U2 TRBL<br />
CANC.)<br />
20 01 Maintenance counter clear<br />
(M-CNT CLR.)<br />
21 01 Maintenance cycle setting<br />
(M-CYCLE)<br />
22 01 Maintenance counter display<br />
(M-CNT)<br />
Contents Details of function/operation<br />
[Function]<br />
When [ENTER/START] key is pressed, the toner motor is rotated for 30sec.<br />
After completion of this process, the machine goes into the main code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
<strong>10</strong>-00 TONER MOTOR<br />
EXECUTING...<br />
[Function]<br />
Used to cancel troubles other than U2.<br />
∗ Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset.<br />
[Operation]<br />
1) Initial display<br />
14-00 TRBL CANC.<br />
CLEARED<br />
[Function]<br />
Used to cancel U2 trouble.<br />
When [ENTER/START] key is pressed, check sum of the total counter in the EEPROM is rewritten<br />
and hardware reset is made.<br />
[Operation]<br />
1) Initial display<br />
16-00 U2 TRBL CANC.<br />
CLEARED<br />
[Function]<br />
When [ENTER/START] key is pressed, the maintenance count value is cleared and "000,000" is displayed.<br />
[Operation]<br />
1) Initial display<br />
20-01 M-CNT CLR.<br />
CLEARED 000,000<br />
[Function]<br />
The code of the currently set maintenance cycle value is displayed (initial display) and the set data<br />
are saved.<br />
Code Setting Remark<br />
0 3,000 sheets<br />
1 6,000 sheets<br />
2 9,000 sheets<br />
3 13,000 sheets<br />
4 25,000 sheets Default<br />
5 Free (999,999 sheets)<br />
[Operation]<br />
1) The current set value is<br />
displayed.<br />
21-01 M-CYCLE<br />
4:25,000 ( 0-5 )<br />
[Function]<br />
The maintenance counter is displayed.<br />
[Operation]<br />
1) Initial display<br />
22-01 M-CNT<br />
***,***<br />
2) [→/<strong>10</strong>KEY]<br />
21-01 M-CYCLE<br />
5:FREE ( 0-5 )<br />
2) [←/<strong>10</strong>KEY]<br />
21-01 M-CYCLE<br />
3:13,000 ( 0-5 )<br />
AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 8<br />
3) [ENTER/START]<br />
21-01 M-CYCLE<br />
5:FREE ( 0-5 )