User's Manual ND 281, NDP 281 - heidenhain - DR. JOHANNES ...
User's Manual ND 281, NDP 281 - heidenhain - DR. JOHANNES ...
User's Manual ND 281, NDP 281 - heidenhain - DR. JOHANNES ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Parameter Settings / Function<br />
Linear error compensation<br />
– 99 999,9 < P41 < + 99 999,9 [µm/m]<br />
Factory setting: 0<br />
Example: Determine input value for P41<br />
Displayed length ............................... Ld = 620.000 mm<br />
Actual length (as determined,<br />
for example, with the VM 101<br />
comparator system<br />
from HEIDENHAIN) ........................... La = 619.877 mm<br />
Difference ......................................... ∆L = La – Ld = – 124 µm<br />
Compensation factor k (= P41):<br />
k = ∆L / Ld = – 123 µm / 0.62 m ....... k = – 198,4 [µm/m]<br />
Reference marks<br />
One reference mark<br />
Distance-coded with 500 • SP<br />
(SP: signal period)<br />
Distance-coded with 1000 SP<br />
(e.g. for HEIDENHAIN LS ...C)<br />
Distance-coded with 2000 SP<br />
Distance-coded with 5000 SP<br />
Reference mark evaluation<br />
Evaluate reference marks<br />
Do not evaluate<br />
reference marks<br />
Parameter Settings / Function<br />
Encoder monitoring<br />
Monitoring not active<br />
Contamination<br />
Frequency<br />
Contamination and frequency<br />
Baud rate<br />
110 / 150 / 300 / 600<br />
1200 / 2400 / 4800 / 9600 baud<br />
Additional blank lines for<br />
data output<br />
0 ≤ P51 ≤ 99<br />
Factory setting: 1<br />
Trigger limit 1<br />
Trigger limit 2<br />
Value for datum point<br />
Enter numerical value for<br />
datum setting over switching input<br />
or with ENT key<br />
List of Operating Parameters<br />
23