Setting Up the Server<br />

1. On the Start menu, point to Settings, and then click Control Panel.<br />

2. In the Control Panel, double-click the Administrative Tools icon.<br />

3. In the Administrative Tools window, double-click the Local Security Policy icon.<br />

4. In the left pane of the Local Security Settings window, expand the Local Policies<br />

tree and select Security Options.<br />

5. In the right pane, right-click Network Security: LAN Manager Authentication<br />

Level and click Properties.<br />

The Local Security Setting dialog box appears.<br />

6. From the LAN Manager Authentication Level list, select Send LM and NTLM<br />

responses. Click OK.<br />

7. Close all the windows and then connect to the <strong>MCP</strong> shares.<br />

Configuring the Optional Uninterruptible Power Supply (UPS)<br />

If your system has an optional UPS feature, you can configure it to shut down the system<br />

in an orderly manner in the event of a site power problem. If your system does not have a<br />

UPS, then skip these instructions.<br />

To set up and configure the UPS connection, per<strong>for</strong>m the following steps:<br />

1. Verify that the RS232 cable is attached from the port on the UPS to one of the two<br />

serial ports on the server unit rear panel.<br />

The Windows environment must be running to configure the UPS using the LAN Safe<br />

III software.<br />

Caution<br />

If the UPS signal cable is not attached, shut down and power off the server unit<br />

be<strong>for</strong>e connecting the cable. Also verify that the site wiring fault alarm is<br />

disabled.<br />

2. With the <strong>MCP</strong> running, from the ODT window enter the CLOSE CDnn, FREE<br />

CDnn, and FREE CTLnn commands. These entries ensure that the CD-ROM drive is<br />

available to Windows.<br />

3. Insert the LAN Safe III CD-ROM in the drive. The CD-ROM is provided with the UPS.<br />

4. On the Start menu, click Run. Click Browse to navigate to the subfolder<br />

/FAILSAFE/NT and the 95/setup.exe file.<br />

5. Invoke the Setup program and click OK to begin the installation.<br />

6. On the FAILSAFE Installation Options screen, select the following:<br />

2–12 3845 8188–000