interoperability c<strong>on</strong>straints and versatility potential. It is a modified versi<strong>on</strong> with respect to an<br />
initial IFREMER proposal included in the KM3Net CDR.<br />
- A major input took its root in the KM3Net project thanks to the technological comparis<strong>on</strong> of<br />
potential technologies for the Sec<strong>on</strong>dary Juncti<strong>on</strong> Box to instrument downlink (cf NIKHEF<br />
studies). Fiber optic communicati<strong>on</strong> and VDSL2 communicati<strong>on</strong> <strong>on</strong> twisted pairs are both<br />
able to cope with the high data rate transmissi<strong>on</strong>.<br />
- A project called DeepSeaNet involving a low cost fiber optic without energy transmissi<strong>on</strong><br />
must also be c<strong>on</strong>sidered for the future. It will allow to collect data from sites situated several<br />
km away from the KM3Net positi<strong>on</strong>, such as geohazard threatened z<strong>on</strong>es. Validati<strong>on</strong> of this<br />
technology is taking place in 2010 <strong>on</strong> Antares site.<br />
- A low cost c<strong>on</strong>necti<strong>on</strong> will be implemented also, allowing to host experiments without<br />
requiring the purchase of expensive c<strong>on</strong>nectors. This feature has been dem<strong>on</strong>strated during<br />
several projects (FP5 Assem for instance) and will be implemented <strong>on</strong> Antares and Neptune<br />
Canada.<br />
- Ancilary functi<strong>on</strong>s are assumed in the juncti<strong>on</strong> box in order to m<strong>on</strong>itor power supply, detect<br />
faults…<br />
- In case of temporary stop of upstream c<strong>on</strong>necti<strong>on</strong> (for instance due to a request by the<br />
neutrino telescope operator), a local storage must be implemented. The implementati<strong>on</strong> of this<br />
feature and the size of the storage will depend <strong>on</strong> the instrumentati<strong>on</strong> setting of the subsea<br />
node.<br />
Node<br />
or<br />
JB 400VDC + Eth<br />
1000LX (fibre)<br />
1 or 2 fibres (fail‐<br />
over, load<br />
balancing,..)<br />
Or<br />
400VDC + xDSL<br />
(few km network<br />
extensi<strong>on</strong>)<br />
October 14th, 2009<br />
Switch(es)<br />
CoS, QoS,<br />
PTP<br />
IEEE 1588<br />
Boundary<br />
clock,<br />
VLAN, LACP,<br />
port<br />
Trunk,…<br />
Extensi<strong>on</strong> module:<br />
RS232/422/485,<br />
CAN Bus,<br />
VDSL2 modem…<br />
Clock synchr<strong>on</strong>izati<strong>on</strong><br />
Ethernet: PTP/IEEE1588 clock client<br />
Other: GPS Emulati<strong>on</strong>‐> PPS + NMEA time code<br />
C<strong>on</strong>troller<br />
Opti<strong>on</strong>al: Data storage<br />
Opti<strong>on</strong>al: Embedded instrument driver<br />
Eth 1000LX (fiber) –400VDC –NTP/PTP IEEE<br />
1588<br />
Eth 1000LX (fiber) –400VDC –NTP/PTP IEEE<br />
1588<br />
Applicati<strong>on</strong>s: Daisy chain for another JB, power<br />
equipments: robotics, vertical profiler…<br />
network extensi<strong>on</strong> up to 20km<br />
Eth 100BT (copper) –48VDC – NTP/PTP IEEE<br />
1588<br />
Eth 100BT (copper) –48VDC – NTP/PTP IEEE<br />
1588<br />
Applicati<strong>on</strong>s: Ethernet scientific instruments,<br />
ex: Seismometer (OBS), still camera , video,<br />
hydroph<strong>on</strong>e, crawler…<br />
RS232/422/485/CAN BUS –48VDC – PPS/NMEA<br />
Applicati<strong>on</strong>s: Serial scientific instruments (with<br />
or without PUCK Protocol) ex: ADCP,<br />
piezometer (pore pressure sensor) ,<br />
seismometer, CTD, chemical analyzer,…<br />
VDSL2 Modem –400VDC – NTP/PTP IEEE 1588<br />
Applicati<strong>on</strong>s: Low cost network extensi<strong>on</strong>,<br />
measurements in water column, instrument or<br />
instrument cluster up to 5‐6km (low cost<br />
extensi<strong>on</strong> (vs. fiber), seismic network, acoustic<br />
network,…<br />
C<strong>on</strong>trol/command<br />
Réseaux câblés et systèmes<br />
power supplies –faults detecti<strong>on</strong><br />
instrumentaux 1<br />
Figure 1: Sec<strong>on</strong>dary juncti<strong>on</strong> box architecture (Smart sensor group – <strong>ESONET</strong>).<br />
<str<strong>on</strong>g>Deliverable</str<strong>on</strong>g> #50 - update October 2010 80