10810 multiMAUS - Fleischmann
10810 multiMAUS - Fleischmann
10810 multiMAUS - Fleischmann
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ERROR MESSAGES<br />
ERR 1: Not compatible for programming.<br />
ERR 2: No confirmation was received from the decoder when programming / reading.<br />
Check whether the connection to the decoder is faulty due to dirt on the tracks or wheel contacts.<br />
Replace the locomotive on the track.<br />
Check whether there is a capacitor somewhere in the track system.<br />
ERR 3: A short circuit has occurred whilst programming / reading.<br />
Check whether the locomotive is placed correctly on the track and make sure the wiring is not<br />
faulty.<br />
The locomotive may be standing on a polarized frog (the turnout setting however does not<br />
match the route of the locomotive).<br />
The decoder may not be connected properly on a converted locomotive.<br />
ERR 4: Not possible in “POM” mode.<br />
This error occurs if the <strong>multiMAUS</strong> is changed over to “POM” mode (page 49) when you are<br />
intending to program CV1 (locomotive address). Program CV1 on a separate section of programming<br />
track in “CV mode” (see page 49).<br />
ERR 5: Programming mode is active.<br />
ERR 6: Not available because track voltage is switched off (occurs in “POM” mode).<br />
ERR 7: The library is empty (menu “LOCO” – “DELETE”).<br />
ERR 8: The library is full (e.g. when entering a new locomotive).<br />
You can save a maximum of 64 locomotives in the library. Control the locomotive using locomotive<br />
address mode or use an additional <strong>multiMAUS</strong>.<br />
ERR 9: The locomotive was not found (menu “LOCO” – “SEARCH”).<br />
The locomotive address has not been created in the library.<br />
ERR 10: A locomotive with the same address already exists (when entering a new locomotive in the<br />
locomotive library).<br />
ERR 11: The locomotive address is outside the valid value range.<br />
You are using a Lokmaus 2, for instance, as the master and it only supports 99 locomotive addresses.<br />
ERR 12: X-PressNet is not compatible with X-Bus.<br />
Only X-PressNet versions 3.0 and above are compatible with the <strong>multiMAUS</strong>.<br />
ERR 13: No X-PressNet master was found.<br />
There is a problem with the device connected to the master output. Unplug the device and reconnect<br />
it. If this does not solve the problem, check the X-Bus address.<br />
ERR 14: The calibration values are invalid.<br />
The controller needs to be recalibrated. See page 52, 3.5.6.<br />
ERR 90 and above:<br />
Your <strong>multiMAUS</strong> is unfortunately in need of service by the ROCO service department.<br />
<br />
59