Design of Plating for Surface Ships, lAW General Specs (Secti<strong>on</strong> 100)<br />

b := —ft a := 24an AR := - AR = 0.246<br />

2 a<br />

Wual •= •'^5'" Thickness of Plate, HTS<br />

H = 12.429ft Head of Water<br />

K := 1 For AR = 0.246, lAW with Table I of <str<strong>on</strong>g>the</str<strong>on</strong>g> General Specs (Secti<strong>on</strong> 100)<br />

C := 400ff^ For HTS, No Set, lAW with Table I of <str<strong>on</strong>g>the</str<strong>on</strong>g> General Specs (Secti<strong>on</strong> 100)<br />

b = short dimensi<strong>on</strong> of <str<strong>on</strong>g>the</str<strong>on</strong>g> panel (inches)<br />

t = thickness of <str<strong>on</strong>g>the</str<strong>on</strong>g> plate (inches)<br />

C = Coefficient that is a functi<strong>on</strong> of <str<strong>on</strong>g>the</str<strong>on</strong>g> plating material and <str<strong>on</strong>g>the</str<strong>on</strong>g> locati<strong>on</strong> of <str<strong>on</strong>g>the</str<strong>on</strong>g> plating <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> ship<br />

b C ■<br />

— < K = coefficient that depends <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> aspect ratio (AR) of <str<strong>on</strong>g>the</str<strong>on</strong>g> panel<br />

K-VH<br />

H = Head of salt water (feet)<br />

K-y/Hb<br />

t, min" p<br />

Wn = 0-52in<br />

The minimum thickness calculated for this secti<strong>on</strong> of plate <str<strong>on</strong>g>to</str<strong>on</strong>g> meet Navy Structural Standards with no set is .52 in. The actual<br />

plate thickness is .75 in. Therefore, stiffening of <str<strong>on</strong>g>the</str<strong>on</strong>g> 2nd deck inner l<strong>on</strong>gitudinal bulkhead plating is not required.<br />

t min «t_actual<br />