OECD SIDS <strong>POTASSIUM</strong> <strong>CHLORIDE</strong><br />
Date: 30-MAR-2003<br />
5. Toxicity Substance ID: <strong>7447</strong>-<strong>40</strong>-7<br />
after the 6-week period. Blood pressure, and<br />
urinary electrolytes (sodium and potassium) and<br />
creatinine, were measured weekly during the<br />
treatment period. Plasma sodium and potassium and<br />
serum albumin, calcium and magnesium were measured<br />
at 6 th week only.<br />
Source:<br />
Norsk Hydro ASA<br />
Reliability: (2) reliable with restrictions<br />
Flag:<br />
non-confidential<br />
01-MAR-2001 (50)<br />
5.5 Genetic Toxicity 'in Vitro'<br />
Type:<br />
Bacterial reverse mutation assay (Salmonella<br />
preincubation assay)<br />
System of<br />
testing: S. typhimurium TA 100, TA 1535, TA 1537, TA 9<br />
Concentration: 0, 100, 333, 1000, 3333, 10000 µg/plate<br />
Cytotoxic Conc.:<br />
Metabolic<br />
activation: with and without<br />
Result: negative<br />
Method:<br />
other, Salmonella preincubation assay (NTP modified<br />
standard plate incorporation assay)<br />
Year: 1986 GLP: no data<br />
Test substance: as prescribed by 1.1-1.4, purity: commercial grade<br />
Remark: Procedure: Pre-incubation. Activation system: S-9<br />
fraction from the liver of Arochlor 254-induced<br />
male SD rats with a NADPH-generating system.<br />
No. replicates: 3 plates per dose level<br />
Source:<br />
Norsk Hydro ASA<br />
Reliability: (2) reliable with restriction<br />
Flag:<br />
Key study for SIDS<br />
01-MAR-2001 (53)<br />
Type:<br />
bacterial colorimetric assay (SOS Chromotest)<br />
System of<br />
testing: E. coli PQ37<br />
Concentration: 1 - 100 000 nM/ml<br />
Metabolic<br />
activation: without<br />
Results:<br />
negative<br />
Method:<br />
other, SOS Chromotest<br />
Year: 1987 GLP: no data<br />
Test substance: as prescribed by 1.1-1.4, purity: commercial grade<br />
Remarks:<br />
No. replicates: 3 plates per dose level.<br />
Source:<br />
Norsk Hydro ASA<br />
Reliability: (2) reliable with restriction<br />
Flag:<br />
non-confidential<br />
01-MAR-2001 (57)<br />
Type:<br />
mammalian cell gene mutation test<br />
System of<br />
testing: mouse lymphoma cell (L5178Y), TK +/- heterozygote<br />
Concentration: 0-5000 µg/ml<br />
Metabolic<br />
72<br />
UNEP PUBLICATIONS