28.01.2014 Views

POTASSIUM CHLORIDE CAS N°: 7447-40-7

POTASSIUM CHLORIDE CAS N°: 7447-40-7

POTASSIUM CHLORIDE CAS N°: 7447-40-7

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OECD SIDS <strong>POTASSIUM</strong> <strong>CHLORIDE</strong><br />

Date: 30-MAR-2003<br />

5. Toxicity Substance ID: <strong>7447</strong>-<strong>40</strong>-7<br />

after the 6-week period. Blood pressure, and<br />

urinary electrolytes (sodium and potassium) and<br />

creatinine, were measured weekly during the<br />

treatment period. Plasma sodium and potassium and<br />

serum albumin, calcium and magnesium were measured<br />

at 6 th week only.<br />

Source:<br />

Norsk Hydro ASA<br />

Reliability: (2) reliable with restrictions<br />

Flag:<br />

non-confidential<br />

01-MAR-2001 (50)<br />

5.5 Genetic Toxicity 'in Vitro'<br />

Type:<br />

Bacterial reverse mutation assay (Salmonella<br />

preincubation assay)<br />

System of<br />

testing: S. typhimurium TA 100, TA 1535, TA 1537, TA 9<br />

Concentration: 0, 100, 333, 1000, 3333, 10000 µg/plate<br />

Cytotoxic Conc.:<br />

Metabolic<br />

activation: with and without<br />

Result: negative<br />

Method:<br />

other, Salmonella preincubation assay (NTP modified<br />

standard plate incorporation assay)<br />

Year: 1986 GLP: no data<br />

Test substance: as prescribed by 1.1-1.4, purity: commercial grade<br />

Remark: Procedure: Pre-incubation. Activation system: S-9<br />

fraction from the liver of Arochlor 254-induced<br />

male SD rats with a NADPH-generating system.<br />

No. replicates: 3 plates per dose level<br />

Source:<br />

Norsk Hydro ASA<br />

Reliability: (2) reliable with restriction<br />

Flag:<br />

Key study for SIDS<br />

01-MAR-2001 (53)<br />

Type:<br />

bacterial colorimetric assay (SOS Chromotest)<br />

System of<br />

testing: E. coli PQ37<br />

Concentration: 1 - 100 000 nM/ml<br />

Metabolic<br />

activation: without<br />

Results:<br />

negative<br />

Method:<br />

other, SOS Chromotest<br />

Year: 1987 GLP: no data<br />

Test substance: as prescribed by 1.1-1.4, purity: commercial grade<br />

Remarks:<br />

No. replicates: 3 plates per dose level.<br />

Source:<br />

Norsk Hydro ASA<br />

Reliability: (2) reliable with restriction<br />

Flag:<br />

non-confidential<br />

01-MAR-2001 (57)<br />

Type:<br />

mammalian cell gene mutation test<br />

System of<br />

testing: mouse lymphoma cell (L5178Y), TK +/- heterozygote<br />

Concentration: 0-5000 µg/ml<br />

Metabolic<br />

72<br />

UNEP PUBLICATIONS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!