NZM10, P10 circuit-breakers and switch-disconnectors<br />
Undervoltage releases, earth-fault releases<br />
10/153<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Contact<br />
sequence<br />
R<strong>at</strong>ed control<br />
voltage 1)<br />
Undervoltage releases, off-delayed<br />
Combin<strong>at</strong>ion of separ<strong>at</strong>e drop-out delay unit and built-in undervoltage release.<br />
U s<br />
V<br />
Type suffix<br />
Article no. for<br />
ordering with<br />
basic unit<br />
Price<br />
See Price<br />
List<br />
Type<br />
Article no. when<br />
ordered separ<strong>at</strong>ely<br />
Price<br />
See Price<br />
List<br />
Std. pack<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
Delay time<br />
0.06 – 16 s<br />
U<br />
D1<br />
D2<br />
AC<br />
DC<br />
24<br />
220 – 240<br />
380 – 440<br />
480 – 550<br />
24<br />
+UVU-NZM10<br />
215192<br />
UVU-NZM10<br />
215191<br />
1 off<br />
Supplementary release coil<br />
<strong>For</strong> UVU-NZM10 delayed undervoltage release, where the drop-out delay unit is<br />
already present<br />
– – – – UV200-NZM10-OAVE<br />
232110<br />
1 off<br />
Notes<br />
1) <strong>For</strong> other control voltages use 50 VA control transformer. Fixing: top-h<strong>at</strong> rail or screws<br />
Contact sequence<br />
R<strong>at</strong>ed control<br />
voltage<br />
U s<br />
V<br />
<strong>For</strong> NZM circuitbreaker/switchdisconnector<br />
Type suffix<br />
Article no. for<br />
ordering with<br />
basic unit<br />
Price<br />
See Price<br />
List<br />
Type<br />
Article no. when<br />
ordered separ<strong>at</strong>ely<br />
Price<br />
See Price<br />
List<br />
Std. pack<br />
Earth-fault release<br />
Not dependent on external voltage, with adjustable r<strong>at</strong>ed fault current<br />
I Dn = 80, 100, 130, 160, 200, 240, 280, 320, 360, 400 A,<br />
With adjustable delay time<br />
t v = 0, 60, 150, 200, 300, 500, 750, 1000 ms<br />
Can be fitted to circuit-breaker<br />
Tripping by a signal direct to the control unit of the switch<br />
6.13 6.21 – 3-pole +TV-NZM10<br />
I∆n<br />
095126<br />
6.14 6.22 – 4-pole +TV-NZM104<br />
095227<br />
<strong>For</strong> separ<strong>at</strong>e mounting<br />
Tripping by shunt release or undervoltage release via<br />
contacts 6.13 – 6.14 or 6.21 – 6.22<br />
I∆n<br />
6.13<br />
6.14<br />
6.21<br />
6.22<br />
TV-NZM10<br />
034811<br />
TV-NZM104<br />
034812<br />
– 3-pole TV-NZM10/E<br />
034813<br />
– 4-pole TV-NZM104/E<br />
034814<br />
1 off<br />
1 off<br />
1 off<br />
1 off<br />
<strong>For</strong> <strong>Immedi<strong>at</strong>e</strong> <strong>Delivery</strong> <strong>call</strong> <strong>KM<strong>Parts</strong></strong>.<strong>com</strong> <strong>at</strong> (866) 595-9616