10/120<br />
Accessories for NZM7 and P7<br />
Auxiliary switches, trip-indic<strong>at</strong>ing auxiliary contacts<br />
Accessories for NZM7 and P7<br />
Auxiliary switches, trip-indic<strong>at</strong>ing auxiliary contacts<br />
10/121<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
NHI standard auxiliary contacts<br />
Switching with the main contacts, used for indic<strong>at</strong>ion and interlock functions.<br />
Two standard auxiliary contacts can be clipped onto the circuit-breaker/switchdisconnector<br />
Contact sequence<br />
1.13<br />
1.14<br />
1.11<br />
1.12<br />
Type suffix<br />
Article no.<br />
When ordered with<br />
basic unit<br />
+EK10<br />
051082<br />
+EK01<br />
051083<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Price<br />
See Price List<br />
Std. pack<br />
1 off EK10<br />
027039<br />
1 off EK01<br />
031785<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Type<br />
Article no. when<br />
ordered separ<strong>at</strong>ely<br />
Price<br />
See Price List<br />
Std. pack<br />
Notes<br />
20 off<br />
20 off<br />
–<br />
–<br />
Auxiliary contacts and voltage releases can be <strong>com</strong>bined as<br />
follows:<br />
In addition to NHI (2 x EK...) and RHI (1 x EK...) a single optional<br />
VHI, A, AVHI, U or U(V)HI can be installed <strong>at</strong> the same time.<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
VHI early-make auxiliary contacts<br />
<strong>For</strong> interlock and load shedding circuits.<br />
3.13 3.33<br />
+VHI-NZM7<br />
051085<br />
1 off VHI-NZM7<br />
051084<br />
1 off Cannot be used in conjunction with R-NZM7<br />
remote oper<strong>at</strong>ors.<br />
3.14 3.34<br />
RHI trip-indic<strong>at</strong>ing auxiliary contacts<br />
General trip indic<strong>at</strong>ion<br />
1 RHI trip-indic<strong>at</strong>ing auxiliary contact as make or break contact insertable in the<br />
circuit-breaker/switch-disconnector.<br />
1.13<br />
1.14<br />
1.11<br />
+EK10<br />
051082<br />
+EK01<br />
051083<br />
1 off EK10<br />
027039<br />
1 off EK01<br />
031785<br />
20 off –<br />
20 off –<br />
1.12<br />
NAGM trip-indic<strong>at</strong>ing auxiliary contact<br />
With short-circuit indic<strong>at</strong>or and standard auxiliary contact,<br />
Allows a differential fault message:<br />
RHI: Tripping through voltage release, overload or short-circuit<br />
AGM: Tripping through short-circuit<br />
NHI: Position of the main contacts<br />
4.23 4.43 4.31 1.33<br />
4.24 4.44 4.32 1.34<br />
RHI AGM AGM NHI<br />
+NAGM-NZM7<br />
051087<br />
1 off Manual reset of the circuit-breaker after a<br />
short-circuit trip:<br />
After a short-circuit, the red short-circuit<br />
indic<strong>at</strong>or must be reset by hand before the<br />
circuit-breaker is restarted.<br />