For Immediate Delivery call KMParts.com at - Moeller Electric Parts
For Immediate Delivery call KMParts.com at - Moeller Electric Parts
For Immediate Delivery call KMParts.com at - Moeller Electric Parts
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Technical d<strong>at</strong>a<br />
Withdrawable, remote oper<strong>at</strong>or, capacitor unit<br />
10/183<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Withdrawable units<br />
Effective power loss<br />
NZM...3-<br />
AE(VE)...630 +<br />
NZM3-XAV<br />
N3-...630<br />
+ NZM3-XAV<br />
NZM...3-<br />
ME...350<br />
+ NZM3-XAV<br />
NZM...3-4-<br />
AE(VE)...630<br />
+ NZM3-4-XAV<br />
N3-4-...630<br />
+ NZM3-4-XAV<br />
NZM...4-<br />
AE(VE)...1600<br />
+ NZM4-XAV<br />
N4-...1600<br />
+ NZM4-XAV<br />
NZM...4-ME...1400<br />
+ NZM4-XAV<br />
220 A W – 25 – – – –<br />
250 A W 32 – 32 – – –<br />
350 A W – 63 – – – –<br />
400 A W 82 – 82 – – –<br />
450 A W – 104 – – – –<br />
550 A W 155 – 155 – 42 –<br />
630 A W – – – 55 – 55<br />
800 A W – – – 90 – 90<br />
875 A W – – – – 107 –<br />
1000 A W – – – 140 – 140<br />
1250 A W – – – 220 – 220<br />
1400 A W – – – – 272 –<br />
1500 A W – – – 312 – 312<br />
1600 A W – – – – – –<br />
NZM...4-4-<br />
AE(VE)...1600<br />
+ NZM4-4-XAV<br />
N4-4-...1600<br />
+ NZM4-4-XAV<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
NZM2-XR... NZM3-XR... NZM4-XR...<br />
Remote oper<strong>at</strong>or<br />
R<strong>at</strong>ed control voltage<br />
U s<br />
AC V AC 48 – 440 48 – 440 48 – 440<br />
DC V DC 24 – 250 24 – 250 24 – 250<br />
Oper<strong>at</strong>ing range AC x U s 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1<br />
DC x U s 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1<br />
R<strong>at</strong>ed power<br />
AC 48 V – 60 V AC VA 350 350 350<br />
110 V – 130 V AC VA 350 350 350<br />
208 V – 240 V AC VA 350 350 350<br />
380 V – 440 V AC VA 350 350 350<br />
DC 24 V – 30 V DC W 250 250 250<br />
48 V – 60 V DC W 250 250 250<br />
110 V – 130 V DC W 250 250 250<br />
220 V – 250 V DC W 250 250 250<br />
Total make time ms 60 80 100<br />
Total opening delay ms 300 1000 3000<br />
Minimum signal dur<strong>at</strong>ion<br />
with switch on ms 30 30 30<br />
with switch off ms 150 250 500<br />
Lifespan, mechanical Oper<strong>at</strong>ions 20000 15000 10000<br />
Maximum oper<strong>at</strong>ing frequency Oper<strong>at</strong>ions/h 120 60 20<br />
Terminal capacity<br />
Solid or flexible conductor with ferrule mm 2 0.75 – 2.5 0.75 – 2.5 0.75 – 2.5<br />
AWG 18 – 14 18 – 14 18 – 14<br />
Capacitor unit for shunt release<br />
NZM-XCM<br />
R<strong>at</strong>ed oper<strong>at</strong>ional voltage U e V AC 230<br />
R<strong>at</strong>ed oper<strong>at</strong>ional current I e mA < 10<br />
Inrush current (peak value) I e A 3<br />
Terminal capacity<br />
Solid or flexible conductor with ferrule mm 2 1 x (0.5 – 2.5)<br />
2 x (0.5 – 1.5)<br />
AWG 1 x (20 – 14)<br />
2 x (20 – 16)<br />
<strong>For</strong> <strong>Immedi<strong>at</strong>e</strong> <strong>Delivery</strong> <strong>call</strong> <strong>KM<strong>Parts</strong></strong>.<strong>com</strong> <strong>at</strong> (866) 595-9616