Technical d<strong>at</strong>a<br />

Withdrawable, remote oper<strong>at</strong>or, capacitor unit<br />

10/183<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

Withdrawable units<br />

Effective power loss<br />

NZM...3-<br />

AE(VE)...630 +<br />

NZM3-XAV<br />

N3-...630<br />

+ NZM3-XAV<br />

NZM...3-<br />

ME...350<br />

+ NZM3-XAV<br />

NZM...3-4-<br />

AE(VE)...630<br />

+ NZM3-4-XAV<br />

N3-4-...630<br />

+ NZM3-4-XAV<br />

NZM...4-<br />

AE(VE)...1600<br />

+ NZM4-XAV<br />

N4-...1600<br />

+ NZM4-XAV<br />

NZM...4-ME...1400<br />

+ NZM4-XAV<br />

220 A W – 25 – – – –<br />

250 A W 32 – 32 – – –<br />

350 A W – 63 – – – –<br />

400 A W 82 – 82 – – –<br />

450 A W – 104 – – – –<br />

550 A W 155 – 155 – 42 –<br />

630 A W – – – 55 – 55<br />

800 A W – – – 90 – 90<br />

875 A W – – – – 107 –<br />

1000 A W – – – 140 – 140<br />

1250 A W – – – 220 – 220<br />

1400 A W – – – – 272 –<br />

1500 A W – – – 312 – 312<br />

1600 A W – – – – – –<br />

NZM...4-4-<br />

AE(VE)...1600<br />

+ NZM4-4-XAV<br />

N4-4-...1600<br />

+ NZM4-4-XAV<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

NZM2-XR... NZM3-XR... NZM4-XR...<br />

Remote oper<strong>at</strong>or<br />

R<strong>at</strong>ed control voltage<br />

U s<br />

AC V AC 48 – 440 48 – 440 48 – 440<br />

DC V DC 24 – 250 24 – 250 24 – 250<br />

Oper<strong>at</strong>ing range AC x U s 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1<br />

DC x U s 0.85 – 1.1 0.85 – 1.1 0.85 – 1.1<br />

R<strong>at</strong>ed power<br />

AC 48 V – 60 V AC VA 350 350 350<br />

110 V – 130 V AC VA 350 350 350<br />

208 V – 240 V AC VA 350 350 350<br />

380 V – 440 V AC VA 350 350 350<br />

DC 24 V – 30 V DC W 250 250 250<br />

48 V – 60 V DC W 250 250 250<br />

110 V – 130 V DC W 250 250 250<br />

220 V – 250 V DC W 250 250 250<br />

Total make time ms 60 80 100<br />

Total opening delay ms 300 1000 3000<br />

Minimum signal dur<strong>at</strong>ion<br />

with switch on ms 30 30 30<br />

with switch off ms 150 250 500<br />

Lifespan, mechanical Oper<strong>at</strong>ions 20000 15000 10000<br />

Maximum oper<strong>at</strong>ing frequency Oper<strong>at</strong>ions/h 120 60 20<br />

Terminal capacity<br />

Solid or flexible conductor with ferrule mm 2 0.75 – 2.5 0.75 – 2.5 0.75 – 2.5<br />

AWG 18 – 14 18 – 14 18 – 14<br />

Capacitor unit for shunt release<br />

NZM-XCM<br />

R<strong>at</strong>ed oper<strong>at</strong>ional voltage U e V AC 230<br />

R<strong>at</strong>ed oper<strong>at</strong>ional current I e mA < 10<br />

Inrush current (peak value) I e A 3<br />

Terminal capacity<br />

Solid or flexible conductor with ferrule mm 2 1 x (0.5 – 2.5)<br />

2 x (0.5 – 1.5)<br />

AWG 1 x (20 – 14)<br />

2 x (20 – 16)<br />