System overview<br />
Circuit-breakers, switch-disconnectors<br />
10/5<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Basic Units<br />
Circuit-breakers 1<br />
R<strong>at</strong>ed uninterrupted current up to 1600 A<br />
Switching capacity 25, 50, 100, 150 kA<br />
<strong>at</strong> 415 V<br />
Adjustable releases<br />
for overload and short-circuit<br />
Adjustable time selectivity<br />
Earth-fault protection<br />
Protection of systems, cables, motors,<br />
gener<strong>at</strong>ors<br />
3 and 4-pole versions,<br />
IEC/EN 60947<br />
a 10/8<br />
Switch-disconnector: 1<br />
R<strong>at</strong>ed uninterrupted current up to 1600 A<br />
Remotely tripped switch-disconnector<br />
with undervoltage or shunt release<br />
3 and 4-pole versions,<br />
IEC/EN 60947<br />
a 10/26<br />
Circuit-breakers for North America 1<br />
R<strong>at</strong>ed uninterrupted current up to 1200 A<br />
Switching capacity 25, 35, 65, 100 kA<br />
<strong>at</strong> 480 V<br />
Adjustable releases<br />
for overload and short-circuit<br />
Adjustable time selectivity<br />
Earth-fault protection<br />
Protection of systems, cables, motors,<br />
gener<strong>at</strong>ors<br />
3-pole version, UL489/CSA5,<br />
IEC/EN 60947<br />
a 10/30<br />
Switch-disconnector for North<br />
America<br />
R<strong>at</strong>ed uninterrupted current up to 1200 A<br />
Remotely tripped switch-disconnector<br />
with undervoltage or shunt release<br />
3-pole version, UL489/CSA5,<br />
IEC/EN 60947<br />
a 10/44<br />
1<br />
Add-on functions<br />
Standard auxiliary contact 11<br />
Switching with the main contacts<br />
Used for indic<strong>at</strong>ion and interlocking tasks<br />
Trip-indic<strong>at</strong>ing auxiliary contact 11<br />
General indic<strong>at</strong>ion of tripping with trip due<br />
to overload or short-circuit as well as<br />
voltage release<br />
Early-make auxiliary contacts 25<br />
<strong>For</strong> interlocking and load shedding<br />
circuits, as well as for early make of the<br />
undervoltage release in main switch/<br />
Emergency-stop applic<strong>at</strong>ions<br />
a 10/46<br />
Voltage releases 25<br />
Undervoltage release<br />
• Non-delayed<br />
• OFF-delayed<br />
Shunt release<br />
a 10/48<br />
Spacers 10<br />
a 10/79<br />
Delay unit for<br />
undervoltage releases<br />
a 10/58<br />
26<br />
Door coupling rotary handle 13, 15<br />
•Lockable<br />
• With door interlock<br />
a 10/72<br />
Main switch rotary handle for<br />
side panel mounting<br />
a 10/76<br />
12<br />
Extension shaft 14<br />
Can be cut to required length.<br />
a 10/72<br />
Rotary handle 16<br />
•Lockable<br />
a 10/74<br />
Remote oper<strong>at</strong>or 19<br />
<strong>For</strong> ON and OFF switching and resetting by<br />
means of 2-wire or 3-wire control.<br />
Mounting accessories<br />
Control circuit terminal 6<br />
<strong>For</strong> two terminals <strong>at</strong> top or bottom<br />
NZM1 a 10/86<br />
NZM2 a 10/90<br />
NZM3 a 10/94<br />
NZM4 a 10/98<br />
Tunnel terminals for Al and Cu cable 5<br />
Standard with control circuit terminal<br />
NZM1 a 10/86<br />
NZM2 a 10/88<br />
NZM3 a 10/92<br />
NZM4 a 10/96<br />
Box terminals 5<br />
Standard equipment of frame size 1<br />
Fitted within the switch housing<br />
NZM1 a 10/86<br />
NZM2 a 10/88<br />
NZM3 a 10/92<br />
Terminal cover 3<br />
Protection against direct contact where<br />
cable lugs, busbars or tunnel terminals are<br />
used<br />
NZM1 a 10/86<br />
NZM2 a 10/90<br />
NZM3 a 10/94<br />
NZM4 a 10/98<br />
Clip pl<strong>at</strong>es 8<br />
NZM1-XC35 a for 35 mm top-h<strong>at</strong> rail<br />
NZM1-XC75 a for 75 mm top-h<strong>at</strong> rail<br />
a 10/79<br />
Rear connection 9<br />
NZM1 a 10/86<br />
NZM2 a 10/90<br />
NZM3 a 10/92<br />
NZM4 a 10/98<br />
Plug-in and withdrawable unit 7<br />
a 10/84<br />
Insul<strong>at</strong>ing surround 18<br />
<strong>For</strong> use with toggle levers, rotary drives<br />
and remote oper<strong>at</strong>ors protruding from the<br />
enclosure<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
a 10/82<br />
Toggle lever interlock device 20<br />
a 10/79<br />
Side oper<strong>at</strong>or handle 21<br />
In prepar<strong>at</strong>ion<br />
a 10/79<br />
External warning pl<strong>at</strong>e/design<strong>at</strong>ion 17<br />
a 10/78<br />
IP2X protection against contact with a<br />
finger<br />
<strong>For</strong> box terminals<br />
2<br />
D<strong>at</strong>a Management Interface<br />
(DMI module)<br />
Access to diagnostics and oper<strong>at</strong>ional d<strong>at</strong>a<br />
Recording of current values<br />
Parameteriz<strong>at</strong>ion and control of the<br />
circuit-breakers with electronic releases<br />
a 10/100<br />
22<br />
EASY-LINK-DS d<strong>at</strong>a plug 23<br />
a 4/14<br />
NZM1 a 10/86<br />
NZM2 a 10/90<br />
NZM3 a 10/94<br />
IP2X protection against contact with a<br />
finger<br />
<strong>For</strong> barrier<br />
NZM1 a 10/86<br />
NZM2 a 10/90<br />
NZM3 a 10/94<br />
4<br />
PROFIBUS-DP interface 24<br />
a 4/9<br />