10/88<br />

Circuit-breakers, switch-disconnectors<br />

NZM2 terminals<br />

Circuit-breakers, switch-disconnectors<br />

NZM2 terminals<br />

10/89<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

Box terminal<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

<strong>For</strong> use with Terminal capacity Terminal capacity Type suffix<br />

Article no.<br />

NZM2, PN2, N2<br />

F 160 A<br />

NZM2, PN2, N2<br />

200 A, 250 A<br />

NZM2-4, PN2-4, N2-4<br />

F 160 A<br />

3-pole<br />

4-pole<br />

Type of conductor Terminal capacity Copper strip Copper busbar<br />

width x<br />

thickness<br />

mm<br />

mmB AWG/MCM mm<br />

Copper cables<br />

Cu cable<br />

1 x 4 – 185<br />

2 x 4 – 70<br />

1 x 12 – 350<br />

2 x 12 – 00<br />

min. 2 x 9 x 0.8<br />

max. 10 x 16 x 0.8<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

when ordered with<br />

basic unit<br />

+NZM2-160-XKCO<br />

262218<br />

+NZM2-160-XKCU<br />

262223<br />

+NZM2-250-XKCO<br />

262242<br />

+NZM2-250-XKCU<br />

262243<br />

+NZM2-4-160-XKCO<br />

266751<br />

+NZM2-4-160-XKCU<br />

266753<br />

Type<br />

Article no.<br />

for separ<strong>at</strong>e order<br />

NZM2-160-XKC<br />

262240<br />

NZM2-250-XKC<br />

262244<br />

NZM2-4-160-XKC<br />

266755<br />

Notes<br />

Type suffix and type contain parts for a circuit-breaker side <strong>at</strong><br />

top or bottom for 3 or 4-pole circuit-breakers.<br />

Conversion kit for circuit-breaker with screw connection.<br />

Fitted within the switch housing<br />

O = for fitting <strong>at</strong> the top<br />

U = for fitting <strong>at</strong> the bottom<br />

U e f 525 V AC:<br />

• Use NZM2(-4)-XKSA cover.<br />

Use with flexible and highly flexible conductors ferrules,<br />

note the max. terminal capacity when using ferrules.<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

NZM2-4, PN2-4, N2-4<br />

200 A, 250 A<br />

+NZM2-4-250-XKCO<br />

266752<br />

+NZM2-4-250-XKCU<br />

266754<br />

NZM2-4-250-XKC<br />

266756<br />

Screw connection<br />

Standard fe<strong>at</strong>ures<br />

NZM2(-4)<br />

PN2(-4), N2(-4)<br />

Three and<br />

four-pole<br />

Copper cable lugs<br />

Aluminium cable lug<br />

1 x 4 – 185<br />

2 x 4 – 70<br />

1 x 10 – 50<br />

2 x 10 – 50<br />

1 x 12 – 000<br />

2 x 4 – 00<br />

1 x 8 – 0<br />

2 x 8 – 0<br />

min. 2 x 16 x 0.8<br />

max. 10 x 16 x 0.8<br />

max. 6 x 24 x 0.5<br />

min. 16 x 5<br />

max. 20 x 5<br />

NZM2-XKS<br />

260030<br />

NZM2-4-XKS<br />

266750<br />

Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />

3 or 4-pole circuit-breakers.<br />

Standard connection with all NZM2, PN2 and N2 circuit-breakers.<br />

Conversion kit for circuit-breaker with box terminal.<br />

Use special cable lug narrow version, a 10/90<br />

Fitted within the switch housing<br />

U e f 525 V AC:<br />

• Use NZM2(-4)-XKSA cover.<br />

If a busbar is used, insul<strong>at</strong>ion (400 mm) and a NZM2(-4)-XKSA<br />

cover are required.<br />

Tunnel terminal<br />

NZM2(-4)<br />

PN2(-4), N2(-4)<br />

Three and<br />

four-pole<br />

Copper cables<br />

Cu cable<br />

Al conductors<br />

Al cable<br />

1 x 16 – 185 1 x 6 – 350 NZM2-XKA<br />

271457<br />

1 x 16 – 185 1) 1 x 6 – 350 NZM2-4-XKA<br />

271458<br />

Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />

3 or 4-pole circuit-breakers.<br />

A standard with control circuit terminal for 1 x 0.75 – 2.5 mm 2<br />

(18 – 14 AWG) or 2 x 0.75 mm 2 (18 – 16 AWG) copper conductors.<br />

Fitted outside the switch housing<br />

Use with flexible and highly flexible conductors ferrules.<br />

NZM2(-4)-XKSA cover necessary (supplied).<br />