11.02.2014 Views

For Immediate Delivery call KMParts.com at - Moeller Electric Parts

For Immediate Delivery call KMParts.com at - Moeller Electric Parts

For Immediate Delivery call KMParts.com at - Moeller Electric Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10/52<br />

Circuit-breakers, switch-disconnectors<br />

Undervoltage release with screw terminals<br />

Circuit-breakers, switch-disconnectors<br />

Undervoltage release with springloaded terminals<br />

10/53<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

Undervoltage release<br />

With two early-make auxiliary contacts<br />

<strong>For</strong> interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in<br />

main-switch applic<strong>at</strong>ions.<br />

D1 3.13<br />

D2<br />

3.14<br />

With clamp terminal on<br />

the left-hand switch side.<br />

<strong>For</strong> use with R<strong>at</strong>ed control voltage Type<br />

U s<br />

V<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

Article no.<br />

for separ<strong>at</strong>e order<br />

NZM1(-4), N1(-4) 24 V 50/60 Hz NZM1-XUHIV24AC<br />

259531<br />

48 V 50/60 Hz NZM1-XUHIV48AC<br />

259533<br />

60 V 50/60 Hz NZM1-XUHIV60AC<br />

259535<br />

110 V – 130 V 50/60 Hz NZM1-XUHIV110-130AC<br />

259537<br />

208 V – 240 V 50/60 Hz NZM1-XUHIV208-240AC<br />

259539<br />

380 V – 440 V 50/60 Hz NZM1-XUHIV380-440AC<br />

259541<br />

480 V – 525 V 50/60 Hz NZM1-XUHIV480-525AC<br />

259543<br />

12 V DC NZM1-XUHIV12DC<br />

259545<br />

24 V DC NZM1-XUHIV24DC<br />

259547<br />

48 V DC NZM1-XUHIV48DC<br />

259549<br />

60V DC<br />

NZM1-XUHIV60DC<br />

259551<br />

110 V – 130 V DC NZM1-XUHIV110-130DC<br />

259553<br />

220 V – 250 V DC NZM1-XUHIV220-250DC<br />

259555<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

D1 3.13<br />

D2<br />

3.14<br />

Type<br />

Article no. when ordered<br />

separ<strong>at</strong>ely<br />

NZM1-XUHIVC24AC<br />

266355<br />

NZM1-XUHIVC48AC<br />

266356<br />

NZM1-XUHIVC60AC<br />

266357<br />

NZM1-XUHIVC110-130AC<br />

266358<br />

NZM1-XUHIVC208-240AC<br />

266359<br />

NZM1-XUHIVC380-440AC<br />

266360<br />

NZM1-XUHIVC480-525AC<br />

266361<br />

NZM1-XUHIVC12DC<br />

266369<br />

NZM1-XUHIVC24DC<br />

266370<br />

NZM1-XUHIVC48DC<br />

266371<br />

NZM1-XUHIVC60DC<br />

266372<br />

NZM1-XUHIVC110-130DC<br />

266373<br />

NZM1-XUHIVC220-250DC<br />

266374<br />

Price<br />

See Price<br />

List<br />

Std. pack<br />

1 off<br />

Notes<br />

When the undervoltage release is de-energized,<br />

accidental contact with the main switches of the switch<br />

during <strong>at</strong>tempts to switch on is safely prevented.<br />

Early make or break with on and off: approx. 20 ms<br />

Cannot be used in conjunction with NZM...-XR...<br />

remote oper<strong>at</strong>or.<br />

Undervoltage releases cannot be installed<br />

simultaneously with NZM...-XHIV... early-make<br />

auxiliary contact or NZM...-XA... shunt release.<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

D1 3.13<br />

D2<br />

3.14<br />

With 3 m connection cable<br />

instead of screw<br />

termin<strong>at</strong>ion.<br />

NZM1(-4), N1(-4) 24 V 50/60 Hz NZM1-XUHIVL24AC<br />

259557<br />

48 V 50/60 Hz NZM1-XUHIVL48AC<br />

259559<br />

60 V 50/60 Hz NZM1-XUHIVL60AC<br />

259561<br />

110 V – 130 V 50/60 Hz NZM1-XUHIVL110-130AC<br />

259563<br />

208 V – 240 V 50/60 Hz NZM1-XUHIVL208-240AC<br />

259565<br />

380 V – 440 V 50/60 Hz NZM1-XUHIVL380-440AC<br />

259567<br />

480 V – 525 V 50/60 Hz NZM1-XUHIVL480-525AC<br />

259569<br />

12 V DC NZM1-XUHIVL12DC<br />

259571<br />

24 V DC NZM1-XUHIVL24DC<br />

259573<br />

48 V DC NZM1-XUHIVL48DC<br />

259575<br />

60V DC<br />

NZM1-XUHIVL60DC<br />

259577<br />

110 V – 130 V DC NZM1-XUHIVL110-130DC<br />

259579<br />

220 V – 250 V DC NZM1-XUHIVL220-250DC<br />

259581<br />

1 off<br />

When the undervoltage release is de-energized,<br />

accidental contact with the main switches of the switch<br />

during <strong>at</strong>tempts to switch on is safely prevented.<br />

Early make or break with on and off: approx. 20 ms<br />

Cannot be used in conjunction with NZM...-XR...<br />

remote oper<strong>at</strong>or.<br />

Undervoltage releases cannot be installed<br />

simultaneously with NZM...-XHIV... early-make<br />

auxiliary contact or NZM...-XA... shunt release.<br />

<strong>For</strong> <strong>Immedi<strong>at</strong>e</strong> <strong>Delivery</strong> <strong>call</strong> <strong>KM<strong>Parts</strong></strong>.<strong>com</strong> <strong>at</strong> (866) 595-9616

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!