10/90<br />
Circuit-breakers, switch-disconnectors<br />
NZM2 terminals<br />
Circuit-breakers, switch-disconnectors<br />
NZM2 terminals<br />
10/91<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
Connection on rear<br />
not UL/CSA approved<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
<strong>For</strong> use with Terminal capacity Terminal capacity Type suffix<br />
Article no.<br />
NZM2(-4)<br />
PN2(-4), N2(-4)<br />
Three and<br />
four-pole<br />
Type of conductor Terminal capacity Copper strip Copper busbar<br />
width x<br />
thickness<br />
mm<br />
mmB AWG/MCM mm<br />
Copper cable lugs<br />
Aluminium cable lug<br />
1 x 4 – 185<br />
2 x 4 – 70<br />
1 x 10 – 50<br />
2 x 10 – 50<br />
– min. 2 x 16 x 0.8<br />
max. 6 x 24 x 0.5<br />
min. 16 x 5<br />
max. 20 x 5<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
when ordered with<br />
basic unit<br />
+NZM2-XKRO<br />
266763<br />
– +NZM2-XKRU<br />
266764<br />
Type<br />
Article no.<br />
for separ<strong>at</strong>e order<br />
NZM2-XKR<br />
266765<br />
Notes<br />
Type suffix and type contain parts for a circuit-breaker side <strong>at</strong><br />
top or bottom for 3 or 4-pole circuit-breakers.<br />
O = for fitting <strong>at</strong> the top<br />
U = for fitting <strong>at</strong> the bottom<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
– +NZM2-4-XKRO<br />
266766<br />
– +NZM2-4-XKRU<br />
266767<br />
NZM2-4-XKR<br />
266768<br />
Control circuit terminal<br />
NZM2(-4)<br />
PN2(-4), N2(-4)<br />
3 and<br />
4-pole<br />
Screw terminal 1 x 0.75 – 4.0<br />
2 x 0.75 – 2.5<br />
1 x 18 – 12<br />
2 x 18 – 14<br />
– – NZM2-XSTS<br />
260156<br />
Box terminal – – NZM-XSTK<br />
266739<br />
Type contains parts for two terminal loc<strong>at</strong>ions loc<strong>at</strong>ed <strong>at</strong> top or<br />
bottom for 3 or 4-pole circuit-breakers.<br />
Included as standard with tunnel terminal<br />
Degree of protection IP1X<br />
NZM-XSTK cannot be <strong>com</strong>bined with NZM2(-4)-XIPK<br />
IP2X protection against contact with a finger.<br />
Cover<br />
NZM2<br />
PN2, N2<br />
NZM2-4<br />
PN2-4, N2-4<br />
IP2X protection against contact with a finger<br />
<strong>For</strong> box terminals<br />
NZM2<br />
PN2, N2<br />
NZM2-4<br />
PN2-4, N2-4<br />
3-pole – – – – – NZM2-XKSA<br />
260038<br />
4-pole – – – – – NZM2-4-XKSA<br />
266770<br />
3-pole – – – – – NZM2-XIPK<br />
266773<br />
4-pole – – – – – NZM2-4-XIPK<br />
266774<br />
Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />
3 or 4-pole circuit-breakers.<br />
Insul<strong>at</strong>ion/protection against direct contact where cable lugs,<br />
busbars or tunnel terminals are used.<br />
Included in set with tunnel terminals<br />
Degree of protection IP4X <strong>at</strong> front, side and rear, on the<br />
connection side when using insul<strong>at</strong>ed conductor m<strong>at</strong>erial to<br />
IP1X.<br />
Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />
3 or 4-pole circuit-breakers.<br />
Enhancement of the protection against direct contact to IP2X.<br />
Protection when reaching into the cable connection area with<br />
the connection of cables in the box terminal.<br />
With 2 conductors minimum cross-section 35 mm 2 or AWG2.<br />
Cannot be <strong>com</strong>bined with NZM-XSTK control circuit terminal.<br />
<strong>For</strong> cover as well as NZM2...(C)NA and N2...NA<br />
NZM2<br />
PN2, N2<br />
NZM2-4<br />
PN2-4, N2-4<br />
Cable lug<br />
not UL/CSA approved<br />
When using cable lugs without NZM2(-4)-XKSA cover, they must be insul<strong>at</strong>ed.<br />
95 mm 2 NZM2(-4)<br />
PN2(-4), N2(-4)<br />
3-pole – – – – – NZM2-XIPA<br />
266777<br />
4-pole – – – – – NZM2-4-XIPA<br />
266778<br />
Threeand<br />
fourpole<br />
Copper conductors<br />
Cu cable<br />
1 x 95 – – – KS95-NZM7<br />
059775<br />
120 mm 2 1 x 120 – – – KS120-NZM7<br />
059776<br />
150 mm 2 1 x 150 – – – KS150-NZM7<br />
059777<br />
185 mm 2 1 x 185 – – – NZM2-XKS185<br />
260032<br />
Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />
3 or 4-pole circuit-breakers.<br />
Only in conjunction with NZM2(-4)-XKSA cover.<br />
Enhancement of the protection against direct contact to IP2X.<br />
When mounting NZM2-..-(C)NA or N2...-NA the following<br />
applies:<br />
With 2 conductors minimum cross-section 35 mm 2 or AWG2.<br />
The type contains a cable lug for 3 or 4-pole switch.<br />
Special cable lug, narrow style<br />
<strong>For</strong> <strong>Immedi<strong>at</strong>e</strong> <strong>Delivery</strong> <strong>call</strong> <strong>KM<strong>Parts</strong></strong>.<strong>com</strong> <strong>at</strong> (866) 595-9616