Circuit-breakers, switch-disconnectors<br />

NZM2 terminals<br />

Circuit-breakers, switch-disconnectors<br />

NZM2 terminals<br />

10/91<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

Connection on rear<br />

not UL/CSA approved<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

<strong>For</strong> use with Terminal capacity Terminal capacity Type suffix<br />

Article no.<br />

NZM2(-4)<br />

PN2(-4), N2(-4)<br />

Three and<br />

four-pole<br />

Type of conductor Terminal capacity Copper strip Copper busbar<br />

width x<br />

thickness<br />

mm<br />

mmB AWG/MCM mm<br />

Copper cable lugs<br />

Aluminium cable lug<br />

1 x 4 – 185<br />

2 x 4 – 70<br />

1 x 10 – 50<br />

2 x 10 – 50<br />

– min. 2 x 16 x 0.8<br />

max. 6 x 24 x 0.5<br />

min. 16 x 5<br />

max. 20 x 5<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

when ordered with<br />

basic unit<br />

+NZM2-XKRO<br />

266763<br />

– +NZM2-XKRU<br />

266764<br />

Type<br />

Article no.<br />

for separ<strong>at</strong>e order<br />

NZM2-XKR<br />

266765<br />

Notes<br />

Type suffix and type contain parts for a circuit-breaker side <strong>at</strong><br />

top or bottom for 3 or 4-pole circuit-breakers.<br />

O = for fitting <strong>at</strong> the top<br />

U = for fitting <strong>at</strong> the bottom<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

– +NZM2-4-XKRO<br />

266766<br />

– +NZM2-4-XKRU<br />

266767<br />

NZM2-4-XKR<br />

266768<br />

Control circuit terminal<br />

NZM2(-4)<br />

PN2(-4), N2(-4)<br />

3 and<br />

4-pole<br />

Screw terminal 1 x 0.75 – 4.0<br />

2 x 0.75 – 2.5<br />

1 x 18 – 12<br />

2 x 18 – 14<br />

– – NZM2-XSTS<br />

260156<br />

Box terminal – – NZM-XSTK<br />

266739<br />

Type contains parts for two terminal loc<strong>at</strong>ions loc<strong>at</strong>ed <strong>at</strong> top or<br />

bottom for 3 or 4-pole circuit-breakers.<br />

Included as standard with tunnel terminal<br />

Degree of protection IP1X<br />

NZM-XSTK cannot be <strong>com</strong>bined with NZM2(-4)-XIPK<br />

IP2X protection against contact with a finger.<br />

Cover<br />

NZM2<br />

PN2, N2<br />

NZM2-4<br />

PN2-4, N2-4<br />

IP2X protection against contact with a finger<br />

<strong>For</strong> box terminals<br />

NZM2<br />

PN2, N2<br />

NZM2-4<br />

PN2-4, N2-4<br />

3-pole – – – – – NZM2-XKSA<br />

260038<br />

4-pole – – – – – NZM2-4-XKSA<br />

266770<br />

3-pole – – – – – NZM2-XIPK<br />

266773<br />

4-pole – – – – – NZM2-4-XIPK<br />

266774<br />

Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />

3 or 4-pole circuit-breakers.<br />

Insul<strong>at</strong>ion/protection against direct contact where cable lugs,<br />

busbars or tunnel terminals are used.<br />

Included in set with tunnel terminals<br />

Degree of protection IP4X <strong>at</strong> front, side and rear, on the<br />

connection side when using insul<strong>at</strong>ed conductor m<strong>at</strong>erial to<br />

IP1X.<br />

Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />

3 or 4-pole circuit-breakers.<br />

Enhancement of the protection against direct contact to IP2X.<br />

Protection when reaching into the cable connection area with<br />

the connection of cables in the box terminal.<br />

With 2 conductors minimum cross-section 35 mm 2 or AWG2.<br />

Cannot be <strong>com</strong>bined with NZM-XSTK control circuit terminal.<br />

<strong>For</strong> cover as well as NZM2...(C)NA and N2...NA<br />

NZM2<br />

PN2, N2<br />

NZM2-4<br />

PN2-4, N2-4<br />

Cable lug<br />

not UL/CSA approved<br />

When using cable lugs without NZM2(-4)-XKSA cover, they must be insul<strong>at</strong>ed.<br />

95 mm 2 NZM2(-4)<br />

PN2(-4), N2(-4)<br />

3-pole – – – – – NZM2-XIPA<br />

266777<br />

4-pole – – – – – NZM2-4-XIPA<br />

266778<br />

Threeand<br />

fourpole<br />

Copper conductors<br />

Cu cable<br />

1 x 95 – – – KS95-NZM7<br />

059775<br />

120 mm 2 1 x 120 – – – KS120-NZM7<br />

059776<br />

150 mm 2 1 x 150 – – – KS150-NZM7<br />

059777<br />

185 mm 2 1 x 185 – – – NZM2-XKS185<br />

260032<br />

Type contains parts for a terminal loc<strong>at</strong>ed <strong>at</strong> top or bottom for<br />

3 or 4-pole circuit-breakers.<br />

Only in conjunction with NZM2(-4)-XKSA cover.<br />

Enhancement of the protection against direct contact to IP2X.<br />

When mounting NZM2-..-(C)NA or N2...-NA the following<br />

applies:<br />

With 2 conductors minimum cross-section 35 mm 2 or AWG2.<br />

The type contains a cable lug for 3 or 4-pole switch.<br />

Special cable lug, narrow style<br />