10/118<br />
P7 switch-disconnectors, 3-pole<br />
Safety switches, 63 – 250 A<br />
P7 switch-disconnectors, 3-pole<br />
Safety switches, 63 – 250 A<br />
10/119<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
Contact sequence Contact sequence R<strong>at</strong>ed<br />
uninterrupted<br />
current<br />
Motor r<strong>at</strong>ing AC-23<br />
220 V<br />
230 V<br />
240 V<br />
380 V<br />
400 V<br />
415 V<br />
500 V 660 V<br />
690 V<br />
I u P P P P<br />
A kW kW kW kW<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
<strong>For</strong> use as Emergency-Stop device<br />
According to IEC/EN 60204-1, VDE 0113<br />
Part 1<br />
With red-yellow door coupling rotary<br />
handle<br />
Lockable in 0 position,<br />
With cover interlock<br />
Degree of protection IP55.<br />
Type<br />
Article no.<br />
Price<br />
See Price List<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Without Emergency-Stop function<br />
With grey door coupling rotary handle,<br />
Lockable in 0 position,<br />
With cover interlock<br />
Degree of protection IP55.<br />
Type<br />
Article no.<br />
Price<br />
See Price List<br />
Std. pack<br />
Enclosure description<br />
insul<strong>at</strong>ed enclosure<br />
Terminals for 5th<br />
conductor (neutral<br />
pole) for fitting by user<br />
Notes<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
Safety switches<br />
LA M<br />
L1 L2 L3 3.14 1.14 1.24<br />
3.13 1.13 1.23<br />
L1 L2 L3<br />
3.14-1.14<br />
1.24-1.23<br />
L1 L2 L3<br />
3.14-1.14<br />
1.24-1.23<br />
63 15 30 37 55 P7-63/CI-RT-SI/LAM<br />
225514<br />
100 30 45 55 90 P7-100/CI-RT-SI/LAM<br />
225515<br />
160 45 75 110 132 P7-160/CI-RT-SI/LAM<br />
225516<br />
200 55 90 132 160 P7-200/CI-RT-SI/LAM<br />
225517<br />
250 70 110 160 215 P7-250/CI-RT-SI/LAM<br />
225518<br />
P7-63/CI-SI/LAM<br />
225519<br />
P7-100/CI-SI/LAM<br />
225520<br />
P7-160/CI-SI/LAM<br />
225521<br />
P7-200/CI-SI/LAM<br />
225522<br />
P7-250/CI-SI/LAM<br />
225523<br />
1 off CI23-150 + 2 x FL2-3 K25/1 Enclosures for separ<strong>at</strong>e mounting, with cable entry. Include<br />
fixing straps for wall mounting.<br />
KST34–150+KS3 K95/1N/BR<br />
Only for switches with terminals.<br />
Degree of protection IP55.<br />
KST34–150+KS3 K95/1N/BR<br />
Not in <strong>com</strong>bin<strong>at</strong>ion with remote oper<strong>at</strong>or.<br />
KST34–150+KS3<br />
CI45-200 + 2 x KS4<br />
K95/1N/BR<br />
K150/1/BR<br />
Notes<br />
Engineering notes<br />
Fe<strong>at</strong>ures<br />
Maintenance, repair and safety switches all<br />
have the same electrical function. They are<br />
designed to safely isol<strong>at</strong>e electrical<br />
install<strong>at</strong>ions (loads) from mains power during<br />
maintenance and repair work and to ensure<br />
th<strong>at</strong> a hazard does not arise which endangers<br />
personnel, machinery and production<br />
m<strong>at</strong>erials.<br />
Safety switches are main switches with an<br />
additional enclosure. Installed in the<br />
immedi<strong>at</strong>e vicinity of the motor or the<br />
electrical load they act as switchdisconnectors<br />
for th<strong>at</strong> load. Provided the five<br />
safety rules defined in VDE 0105 are observed,<br />
they should ensure a safe working<br />
environment. This is particularly important if<br />
there is any danger of the main switch being<br />
inadvertently oper<strong>at</strong>ed.<br />
Applic<strong>at</strong>ion<br />
By securing the switch in the OFF position with<br />
his own padlock (up to three can be fitted), the<br />
fitter/electrician can protect himself against<br />
the possibility of any other person switching<br />
the machine on.<br />
Maintenance switches are merely additional,<br />
enclosed main switches with a padlocking<br />
facility.<br />
Safety switches are housed in insul<strong>at</strong>ed<br />
enclosures and bear the inscription “Safety<br />
switch” on a bright orange label. Labels are<br />
available in other languages.<br />
Switches to be used as Emergency-Stop<br />
devices have a special red handle with a<br />
yellow locking collar in accordance with STOP<br />
c<strong>at</strong>egory 0 as defined by IEC/EN 60204. If the<br />
switch is not approved as an Emergency-Stop<br />
switch, both parts are grey.<br />
The cover and handle can be interlocked by<br />
fitting a padlock.<br />
Selection<br />
Switches must be selected according to the<br />
following criteria:<br />
• The motor switching capacity, where the<br />
switch is fitted in such a way th<strong>at</strong> the<br />
oper<strong>at</strong>or may use it for oper<strong>at</strong>ional ON and<br />
OFF switching.<br />
• The r<strong>at</strong>ing d<strong>at</strong>a always applies for 3 poles.<br />
When the motor r<strong>at</strong>ing is divided between 6<br />
poles, such as for star-delta switching, a 6-<br />
pole switch can be used to control 1.73<br />
times the r<strong>at</strong>ed power.<br />
• If the switch has a load-shedding contact<br />
(LA), you can select the appropri<strong>at</strong>e switch<br />
according to the uninterrupted current. The<br />
load-shedding contact is an auxiliary<br />
contact, which is closed in the ON position<br />
and opens early when switching off, so th<strong>at</strong><br />
a contactor loc<strong>at</strong>ed in the circuit takes over<br />
the switching capacity and the<br />
maintenance/safety switch oper<strong>at</strong>es <strong>at</strong> zero<br />
load. When switching on, the load-shedding<br />
contact closes l<strong>at</strong>er than or <strong>at</strong> the same time<br />
as the main contacts. This is achieved by<br />
connecting an early-make auxiliary contact<br />
(VHI) and a standard auxiliary contact (NHI)<br />
in series.<br />
• If the switch is prevented from switching<br />
under load, you can also select it according<br />
to the continuous current. With a suitable<br />
handle and collar, you can, for example,<br />
lock the switch in its ON position. This is not<br />
permissible for switches with a red/yellow<br />
handle.<br />
Safety switch with load shedding and annunci<strong>at</strong>ion (example)<br />
L1<br />
L2<br />
L3<br />
PEN<br />
Q 100<br />
K10<br />
Safety switch<br />
Q10<br />
0 I<br />
1<br />
2<br />
3<br />
4<br />
M<br />
3~<br />
5<br />
6<br />
VHI<br />
NHI<br />
LA<br />
M<br />
H10<br />
F1<br />
Q100-S1<br />
0<br />
S10<br />
I<br />
K10<br />
K10<br />