Circuit-breakers for North America<br />
Magnetic short-circuit release, 3-pole<br />
Circuit-breakers for North America<br />
Magnetic short-circuit release, 3-pole<br />
10/37<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
R<strong>at</strong>ed current = r<strong>at</strong>ed<br />
uninterrupted current<br />
Setting range<br />
Overload releases<br />
I n = I u I r I i<br />
A A A<br />
Short-circuitrelease<br />
Short-circuit protection<br />
Motor protection in conjunction with contactor and overload relay<br />
• With short-circuit release<br />
• Without overload release<br />
I<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Basic switching capacity<br />
Normal switching capacity<br />
High switching capacity<br />
600 V 2) 600 V 2) 600 V 2)<br />
480 V 1)<br />
480 V 1)<br />
480 V 1)<br />
Type<br />
Article no.<br />
Price<br />
See Price List<br />
Type<br />
Article no.<br />
Price<br />
See Price List<br />
Type<br />
Article no.<br />
Price<br />
See Price List<br />
Std. pack<br />
Notes<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
3-pole<br />
Terminal screws standard<br />
terminals as accessories<br />
1.6 – 12.8 – 22.4 NZMB2-S1,6-CNA<br />
269472<br />
2.4 – 19.2 – 33.6 NZMB2-S2,4-CNA<br />
269473<br />
4 – 32 – 56 NZMB2-S4-CNA<br />
269476<br />
6 – 48 – 84 NZMB2-S6-CNA<br />
269477<br />
10 – 80 – 140 NZMB2-S10-CNA<br />
269239<br />
16 – 128 – 224 NZMB2-S16-CNA<br />
269240<br />
25 – 200 – 350 NZMB2-S25-CNA<br />
269241<br />
32 – 256 – 448 NZMB2-S32-CNA<br />
269242<br />
40 – 320 – 560 NZMB2-S40-CNA<br />
269243<br />
50 – 400 – 700 NZMB2-S50-CNA<br />
269244<br />
63 – 504 – 882 NZMB2-S63-CNA<br />
269245<br />
80 – 640 – 1120 NZMB2-S80-CNA<br />
269246<br />
100 – 800 – 1400 NZMB2-S100-CNA<br />
269247<br />
125 – 1000 – 1750 NZMB2-S125-CNA<br />
269248<br />
160 – 1280 – 2240 NZMB2-S160-CNA<br />
269249<br />
200 – 1600 – 2500 NZMB2-S200-CNA<br />
269250<br />
NZMN2-S1,6-CNA<br />
269478<br />
NZMN2-S2,4-CNA<br />
269479<br />
NZMN2-S4-CNA<br />
269480<br />
NZMN2-S6-CNA<br />
269481<br />
NZMN2-S10-CNA<br />
269251<br />
NZMN2-S16-CNA<br />
269252<br />
NZMN2-S25-CNA<br />
269253<br />
NZMN2-S32-CNA<br />
269254<br />
NZMN2-S40-CNA<br />
269255<br />
NZMN2-S50-CNA<br />
269256<br />
NZMN2-S63-CNA<br />
269257<br />
NZMN2-S80-CNA<br />
269258<br />
NZMN2-S100-CNA<br />
269259<br />
NZMN2-S125-CNA<br />
269260<br />
NZMN2-S160-CNA<br />
269261<br />
NZMN2-S200-CNA<br />
269262<br />
NZMH2-S1,6-CNA<br />
269482<br />
NZMH2-S2,4-CNA<br />
269483<br />
NZMH2-S4-CNA<br />
269484<br />
NZMH2-S6-CNA<br />
269485<br />
NZMH2-S10-CNA<br />
269263<br />
NZMH2-S16-CNA<br />
269264<br />
NZMH2-S25-CNA<br />
269265<br />
NZMH2-S32-CNA<br />
269266<br />
NZMH2-S40-CNA<br />
269267<br />
NZMH2-S50-CNA<br />
269268<br />
NZMH2-S63-CNA<br />
269269<br />
NZMH2-S80-CNA<br />
269270<br />
NZMH2-S100-CNA<br />
269271<br />
NZMH2-S125-CNA<br />
269272<br />
NZMH2-S160-CNA<br />
269273<br />
NZMH2-S200-CNA<br />
269274<br />
1 off Switches conform to UL/CSA as well as the IEC regul<strong>at</strong>ions.<br />
40 IEC switching performance values from 40 A are contained on the<br />
r<strong>at</strong>ing pl<strong>at</strong>e.<br />
Technical d<strong>at</strong>a a page 10/180<br />
UL 489, CSA-C22.2-5.1, IEC/EN 60947-2<br />
Adjustable short-circuit release I i<br />
• 8 – 14 x I n (ex-factory 12 x I n )<br />
– NZM...2-S200-CNA, 8 – 12.5 x I n (ex-factory 12 x I n )<br />
Without overload release I r<br />
CNA: The device has <strong>com</strong>ponents approved to UL, the conditions<br />
of approval must be observed during use,<br />
i.e. the device must be <strong>com</strong>bined with a suitable contactor and<br />
overload relay.<br />
A switching capacity is st<strong>at</strong>ed for the <strong>com</strong>plete motor-starter<br />
<strong>com</strong>bin<strong>at</strong>ion.<br />
The device is approved as a CSA approved single device.<br />
1) With NZM...2-...-NA the following applies: 480 Y/277 V AC probably<br />
until June 2004<br />
2) Probably from June 2004: 600 V<br />
Notes Notes for terminals a 10/86<br />