10/46<br />

Circuit-breakers, switch-disconnectors<br />

Auxiliary contact with screw terminals<br />

Circuit-breakers, switch-disconnectors<br />

Auxiliary switches with springloaded terminals<br />

10/47<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

<strong>For</strong> use with<br />

Auxiliary contacts<br />

Standard auxiliary contact (HIN)<br />

Switching with the main contacts<br />

Used for indic<strong>at</strong>ing and interlocking tasks<br />

– NZM1(-4), 2(-4), 3(-4), 4(-4)<br />

PN1(-4), 2(-4), 3(-4)<br />

N1(-4), 2(-4), 3(-4), 4(-4)<br />

With 3 m connection cable<br />

instead of screw termin<strong>at</strong>ion.<br />

NZM1(-4)<br />

PN1(-4)<br />

N1(-4)<br />

Contacts<br />

M = make contact,<br />

B = break contact<br />

f = positive<br />

opening safety<br />

function to<br />

IEC/EN 60947-5-1<br />

Contact<br />

sequence<br />

Type<br />

Article no.<br />

for separ<strong>at</strong>e<br />

order<br />

1 M – 1.X3<br />

M22-K10<br />

216376<br />

1.X4<br />

– 1 B f 1.X1<br />

M22-K01<br />

216378<br />

1.X2<br />

1 M 1 B f 1.X3 1.X1 NZM-XHI11L<br />

266098<br />

1.X4<br />

1.X2<br />

2 M – 1.X3 1.X3 NZM-XHI20L<br />

266099<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

Price<br />

See Price<br />

List<br />

Std. pack<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

Type<br />

Article no.<br />

for separ<strong>at</strong>e order<br />

20 off M22-CK10<br />

216384<br />

20 off M22-CK01<br />

216385<br />

1 off<br />

Price<br />

See Price<br />

List<br />

Std. pack<br />

Notes<br />

20 off The following can be clipped into the switches:<br />

• NZM1 – a standard auxiliary contact<br />

• NZM2 up to two M22-K... standard auxiliary contacts<br />

20 off<br />

• NZM3 as well as NZM4 - up to 3 standard auxiliary contacts<br />

M22-(C)K...<br />

Any <strong>com</strong>bin<strong>at</strong>ions of the auxiliary contact types is<br />

possible.<br />

Marking on switch: HIN<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

1.X4<br />

1.X4<br />

– 2 B f 1.X1 1.X1 NZM-XHI02L<br />

266170<br />

1.X2 1.X2<br />

Early-make auxiliary contacts<br />

<strong>For</strong> interlock and load-shedding circuits<br />

With clamp terminal on the<br />

left-hand switch side.<br />

NZM1(-4)<br />

PN1(-4)<br />

N1(-4)<br />

2 M – 3.13 3.23 NZM1-XHIV<br />

259426<br />

3.14 3.24<br />

1 off NZM1-XHIVC<br />

266176<br />

1 off – Not in conjunction with<br />

NZM...-XU(C)... undervoltage release, NZM...-XA(C)...<br />

shunt release<br />

or NZM...-XR... remote oper<strong>at</strong>or<br />

Early action with make or break: approx. 20 ms<br />

With 3 m connection cable<br />

instead of screw termin<strong>at</strong>ion.<br />

NZM1(-4)<br />

PN1(-4)<br />

N1(-4)<br />

2 M – 3.13 3.23 NZM1-XHIVL<br />

259432<br />

3.14 3.24<br />

– NZM2(-4), 3(-4)<br />

PN2(-4), 3(-4)<br />

N2(-4), 3(-4)<br />

2 M – 3.13 3.23 NZM2/3-XHIV<br />

259430<br />

3.14 3.24<br />

NZM2/3-XHIVC<br />

266178<br />

1 off –<br />

NZM4(-4)<br />

N4(-4)<br />

2 M – 3.13 3.23 NZM4-XHIV<br />

266172<br />

3.14 3.24<br />

1 off NZM4-XHIVC<br />

266180<br />

1 off – Not in conjunction with<br />

NZM...-XU(C)... undervoltage release, NZM...-XA(C)...<br />

shunt release<br />

or NZM...-XR... remote oper<strong>at</strong>or<br />

Early action by make: approx. 90 ms<br />

Trip indic<strong>at</strong>ing auxiliary contact (HIA)<br />

General trip indic<strong>at</strong>ion '+', when tripped by voltage release, overload release or short-circuit release<br />

– NZM1(-4), 2(-4), 3(-4), 4(-4)<br />

PN1(-4), 2(-4), 3(-4)<br />

N1(-4), 2(-4), 3(-4), 4(-4)<br />

With 3 m connection cable<br />

instead of screw termin<strong>at</strong>ion.<br />

NZM1(-4)<br />

PN1(-4)<br />

N1(-4)<br />

1 M – 4.X3<br />

M22-K10<br />

216376<br />

4.X4<br />

– 1 B f 4.X1<br />

M22-K01<br />

216378<br />

4.X2<br />

1 M 1 B f 4.X3 4.X1 NZM-XHI11L<br />

266098<br />

4.X4 4.X2<br />

2 M – 4.X3 4.X3 NZM-XHI20L<br />

266099<br />

20 off M22-CK10<br />

216384<br />

20 off M22-CK01<br />

216385<br />

1 off<br />

20 off The following can be clipped into the switches:<br />

• NZM1 - one trip-indic<strong>at</strong>ing auxiliary switch<br />

• NZM2 - one M22-(C)K... trip-indic<strong>at</strong>ing auxiliary switch<br />

20 off<br />

• NZM3 - one M22-(C)K... trip-indic<strong>at</strong>ing auxiliary switch<br />

• NZM4 - up to 2 M22-(C)K... trip-indic<strong>at</strong>ing auxiliary<br />

switches<br />

Any <strong>com</strong>bin<strong>at</strong>ions of the auxiliary contact types is<br />

possible.<br />

Marking on switch: HIA<br />

4.X4 4.X4<br />

– 2 B f 4.X1 4.X1 NZM-XHI02L<br />

266170<br />

4.X2 4.X2<br />