10/46<br />
Circuit-breakers, switch-disconnectors<br />
Auxiliary contact with screw terminals<br />
Circuit-breakers, switch-disconnectors<br />
Auxiliary switches with springloaded terminals<br />
10/47<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
<strong>For</strong> use with<br />
Auxiliary contacts<br />
Standard auxiliary contact (HIN)<br />
Switching with the main contacts<br />
Used for indic<strong>at</strong>ing and interlocking tasks<br />
– NZM1(-4), 2(-4), 3(-4), 4(-4)<br />
PN1(-4), 2(-4), 3(-4)<br />
N1(-4), 2(-4), 3(-4), 4(-4)<br />
With 3 m connection cable<br />
instead of screw termin<strong>at</strong>ion.<br />
NZM1(-4)<br />
PN1(-4)<br />
N1(-4)<br />
Contacts<br />
M = make contact,<br />
B = break contact<br />
f = positive<br />
opening safety<br />
function to<br />
IEC/EN 60947-5-1<br />
Contact<br />
sequence<br />
Type<br />
Article no.<br />
for separ<strong>at</strong>e<br />
order<br />
1 M – 1.X3<br />
M22-K10<br />
216376<br />
1.X4<br />
– 1 B f 1.X1<br />
M22-K01<br />
216378<br />
1.X2<br />
1 M 1 B f 1.X3 1.X1 NZM-XHI11L<br />
266098<br />
1.X4<br />
1.X2<br />
2 M – 1.X3 1.X3 NZM-XHI20L<br />
266099<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Price<br />
See Price<br />
List<br />
Std. pack<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
Type<br />
Article no.<br />
for separ<strong>at</strong>e order<br />
20 off M22-CK10<br />
216384<br />
20 off M22-CK01<br />
216385<br />
1 off<br />
Price<br />
See Price<br />
List<br />
Std. pack<br />
Notes<br />
20 off The following can be clipped into the switches:<br />
• NZM1 – a standard auxiliary contact<br />
• NZM2 up to two M22-K... standard auxiliary contacts<br />
20 off<br />
• NZM3 as well as NZM4 - up to 3 standard auxiliary contacts<br />
M22-(C)K...<br />
Any <strong>com</strong>bin<strong>at</strong>ions of the auxiliary contact types is<br />
possible.<br />
Marking on switch: HIN<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
1.X4<br />
1.X4<br />
– 2 B f 1.X1 1.X1 NZM-XHI02L<br />
266170<br />
1.X2 1.X2<br />
Early-make auxiliary contacts<br />
<strong>For</strong> interlock and load-shedding circuits<br />
With clamp terminal on the<br />
left-hand switch side.<br />
NZM1(-4)<br />
PN1(-4)<br />
N1(-4)<br />
2 M – 3.13 3.23 NZM1-XHIV<br />
259426<br />
3.14 3.24<br />
1 off NZM1-XHIVC<br />
266176<br />
1 off – Not in conjunction with<br />
NZM...-XU(C)... undervoltage release, NZM...-XA(C)...<br />
shunt release<br />
or NZM...-XR... remote oper<strong>at</strong>or<br />
Early action with make or break: approx. 20 ms<br />
With 3 m connection cable<br />
instead of screw termin<strong>at</strong>ion.<br />
NZM1(-4)<br />
PN1(-4)<br />
N1(-4)<br />
2 M – 3.13 3.23 NZM1-XHIVL<br />
259432<br />
3.14 3.24<br />
– NZM2(-4), 3(-4)<br />
PN2(-4), 3(-4)<br />
N2(-4), 3(-4)<br />
2 M – 3.13 3.23 NZM2/3-XHIV<br />
259430<br />
3.14 3.24<br />
NZM2/3-XHIVC<br />
266178<br />
1 off –<br />
NZM4(-4)<br />
N4(-4)<br />
2 M – 3.13 3.23 NZM4-XHIV<br />
266172<br />
3.14 3.24<br />
1 off NZM4-XHIVC<br />
266180<br />
1 off – Not in conjunction with<br />
NZM...-XU(C)... undervoltage release, NZM...-XA(C)...<br />
shunt release<br />
or NZM...-XR... remote oper<strong>at</strong>or<br />
Early action by make: approx. 90 ms<br />
Trip indic<strong>at</strong>ing auxiliary contact (HIA)<br />
General trip indic<strong>at</strong>ion '+', when tripped by voltage release, overload release or short-circuit release<br />
– NZM1(-4), 2(-4), 3(-4), 4(-4)<br />
PN1(-4), 2(-4), 3(-4)<br />
N1(-4), 2(-4), 3(-4), 4(-4)<br />
With 3 m connection cable<br />
instead of screw termin<strong>at</strong>ion.<br />
NZM1(-4)<br />
PN1(-4)<br />
N1(-4)<br />
1 M – 4.X3<br />
M22-K10<br />
216376<br />
4.X4<br />
– 1 B f 4.X1<br />
M22-K01<br />
216378<br />
4.X2<br />
1 M 1 B f 4.X3 4.X1 NZM-XHI11L<br />
266098<br />
4.X4 4.X2<br />
2 M – 4.X3 4.X3 NZM-XHI20L<br />
266099<br />
20 off M22-CK10<br />
216384<br />
20 off M22-CK01<br />
216385<br />
1 off<br />
20 off The following can be clipped into the switches:<br />
• NZM1 - one trip-indic<strong>at</strong>ing auxiliary switch<br />
• NZM2 - one M22-(C)K... trip-indic<strong>at</strong>ing auxiliary switch<br />
20 off<br />
• NZM3 - one M22-(C)K... trip-indic<strong>at</strong>ing auxiliary switch<br />
• NZM4 - up to 2 M22-(C)K... trip-indic<strong>at</strong>ing auxiliary<br />
switches<br />
Any <strong>com</strong>bin<strong>at</strong>ions of the auxiliary contact types is<br />
possible.<br />
Marking on switch: HIA<br />
4.X4 4.X4<br />
– 2 B f 4.X1 4.X1 NZM-XHI02L<br />
266170<br />
4.X2 4.X2<br />
<strong>For</strong> <strong>Immedi<strong>at</strong>e</strong> <strong>Delivery</strong> <strong>call</strong> <strong>KM<strong>Parts</strong></strong>.<strong>com</strong> <strong>at</strong> (866) 595-9616