08.03.2014 Views

Download the 2011 Program Book - Traditional Poster ... - ismrm

Download the 2011 Program Book - Traditional Poster ... - ismrm

Download the 2011 Program Book - Traditional Poster ... - ismrm

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Poster</strong> Sessions<br />

Malmö University Hospital, Malmö, Sweden; 6 Department of Radiology, University of Virginia, Charlottesville, VA, United States;<br />

7 Pulmonary, Allergy & Critical Care Division, University of Pennsylvania, Philadelphia, PA, United States; 8 Otolaryngology–Head &<br />

Neck Surgery, Johns Hopkins University, Baltimore, MD, United States<br />

910. Imaging of Localized Inert Gas Washout Rates with 3 He MRI<br />

Martin Heiner Deppe 1 , Xiaojun Peggy Xu 1 , Steven R. Parnell 1 , Jim M. Wild 1<br />

1 Academic Unit of Radiology, University of Sheffield, Sheffield, South Yorkshire, United Kingdom<br />

911. Exploring Ventilation & Perfusion Matching in COPD with 3 He Ventilation & DCE 1 H Perfusion MRI<br />

Helen Marshall 1 , Martin H. Deppe 1 , Juan Parra Robles 1 , Steve R. Parnell 1 , Rob H. Ireland 1 , David Capener 1 , Sue<br />

Hillis 1 , Smitha Rajaram 1 , Ca<strong>the</strong>rine Billings 2 , David A. Lipson 3 , Rod Lawson 2 , Jim M. Wild 1<br />

1 Academic Radiology, University of Sheffield, Sheffield, South Yorkshire, United Kingdom; 2 Respiratory Medicine, University of<br />

Sheffield, Sheffield, South Yorkshire, United Kingdom; 3 GlaxoSmithKline, King of Prussia, PA, United States<br />

912. Improved Phase-Based Transmitter Calibration for Hyperpolarized-Gas MRI using Shinnar-Le Roux RF<br />

Pulses<br />

Kun Qing 1 , Grady Wilson Miller 2,3 , Talissa Altes 2 , Jaime F. Horta Coelho Mata 2 , Eduard E. De Lange 2 , William A.<br />

Tobias 3 , Gordon D. Cates 3 , James R. Brookeman 2 , John Philip Mugler 1,2<br />

1 Biomedical Engineering, University of Virginia, Charlottesville, VA, United States; 2 Radiology, University of Virginia; 3 Physics,<br />

University of Virginia<br />

913. Sensitivity of Transmit Coil B 1 + to Lung Inflation in Hyperpolarised 3 He MRI<br />

Jim M. Wild 1 , Martin H. Deppe 1 , Salma Ajraoui 1 , Helen Marshall 1 , Graham Norquay 1 , Titus Lanz 2 , Matthias Behr 2 ,<br />

Francesco Padormo 3 , Juan Parra-Robles 1 , Sebastian Kozerke 4<br />

1 University of Sheffield, Sheffield, Yorkshire, United Kingdom; 2 Rapid Biomedical; 3 Imperial College, United Kingdom; 4 Imaging<br />

Sciences, Kings College London<br />

914. Quantification of Aerosol Deposition in <strong>the</strong> Upper Airways: A Multimodality Study<br />

Mathieu Sarracanie 1 , Denis Grebenkov 2 , Soule Coulibaly 1 , Andrew Martin 3 , Kyle Hill 4 , Jose Manuel Perez-Sanchez 1 ,<br />

Redouane Fodil 5 , Lionel Martin 1 , Emmanuel Durand 1 , Georges Caillibotte 3 , Daniel Isabey 5 , Luc Darrasse 1 , Jacques<br />

Bittoun 1 , Xavier Maitre 1<br />

1 IR4M (UMR8081), Univ Paris-Sud, CNRS, Orsay, France; 2 Laboratoire de Physique de la Matiere Condensee (UMR7643), Ecole<br />

Polytechnique, CNRS, Palaiseau, France; 3 Centre de Recherche Claude Delorme (CRCD), Air Liquide, Les Loges-en-Josas, France;<br />

4 Radiology Research Group, Oxford MRI Centre, Oxford University, Oxford, United Kingdom; 5 Biomecanique Cellulaire et<br />

Respiratoire (U955), IMRB, Inserm, Creteil, France<br />

915. Analytical Description of Long Time Scale Diffusion MRI of <strong>the</strong> Human Lung<br />

Niels Buhl 1,2 , Sune Nørhøj Jespersen 2<br />

1 Department of Physics & Astronomy, Aarhus University, Aarhus, Denmark; 2 Center of Functionally Integrative Neuroscience,<br />

Aarhus University Hospital, Aarhus, Denmark<br />

916. Finite Element Simulations of 129 Xe Gas Diffusion in Models of Lung Airways<br />

Juan Parra-Robles 1 , Steven R. Parnell 1 , Salma Ajraoui 1 , Xiaojun Xu 1 , Jim M. Wild 1<br />

1 Academic Radiology, University of Sheffield, Sheffield, South Yorkshire, United Kingdom<br />

917. Finite Element Simulations of Short-Range 3 He Diffusion in a Model of Branching Acinar Airways: Implications<br />

for In Vivo Lung Morphmetry<br />

Juan Parra-Robles 1 , Steven R. Parnell 1 , Salma Ajraoui 1 , Xiaojun Xu 1 , Jim M. Wild 1<br />

1 Academic Radiology, University of Sheffield, Sheffield, South Yorkshire, United Kingdom<br />

918. The Impact of Sub-Optimal Pulse Sequence Implementations on XTC MRI Measurements<br />

Kai Ruppert 1 , Ching-Ling Teng 1 , Isabel M. Dregely 2 , Jaime F. Mata 1 , Talissa A. Altes 1 , G. Wilson Miller 1 , John P.<br />

Mugler III 1<br />

1 University of Virginia, Charlottesville, VA, United States; 2 University of New Hampshire, Durham, NH, United States<br />

Lung MRI<br />

Exhibition Hall Thursday 13:30-15:30<br />

919. Magnetic Resonance Elastography of <strong>the</strong> Lung Parenchyma: Correlation of Shear Stiffness with Airway<br />

Opening Pressures<br />

Yogesh Kannan Mariappan 1 , Arunark Kolipaka 1 , Rolf D. Hubmayr 2 , Richard L. Ehman 1 , Phillip Araoz 1 , Kiaran P.<br />

McGee 1<br />

1 Department of Radiology, Mayo Clinic, Rochester, MN, United States; 2 Department of Pulmonary & Critical Care medicine, Mayo<br />

Clinic, Rochester, MN, United States<br />

121

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!