08.03.2014 Views

Download the 2011 Program Book - Traditional Poster ... - ismrm

Download the 2011 Program Book - Traditional Poster ... - ismrm

Download the 2011 Program Book - Traditional Poster ... - ismrm

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Poster</strong> Sessions<br />

Contrast Enhanced MRA (Non Coronary)<br />

Exhibition Hall Wednesday 13:30-15:30<br />

1293. Magnetic Resonance T 1 Mapping Predicts Successful Venous Thrombolysis<br />

Prakash Saha 1 , Marcelo E. Andia 2 , Ulrike Blume 2 , Andrea J. Wiethoff 2,3 , Tobias Schaeffter 2 , Colin Evans 1 , Anwar<br />

Ahmad 1 , Ashish Patel 1 , Bijan Modarai 1 , Rene M. Botnar 2 , Albert Smith 1 , Mat<strong>the</strong>w Waltham 1<br />

1 Academic Department of Surgery, Cardiovascular Division, Kings College London, London, United Kingdom; 2 Division of Imaging<br />

Sciences & Biomedical Engineering, Kings College London, London, United Kingdom; 3 Philips Healthcare, Guildford, United<br />

Kingdom<br />

1294. MRI Pulmonary Perfusion Imaging as a Quantitative Predictor of Regional Pulmonary Vascular Resistance in<br />

Pulmonary Hypertension<br />

Adam Telfer 1 , Robin Condliffe 2 , David Capener 1 , Andrew Swift 1 , Smitha Rajaram 1 , Helen Marshall 1 , Judith Hurdman 2 ,<br />

Charles Elliot 2 , David Kiely 2 , Jim Wild 1<br />

1 Academic Radiology Unit, University of Sheffield, Sheffield, South Yorkshire, United Kingdom; 2 Pulmonary Vascular Diseases<br />

Unit, Sheffield Teaching Hospitals, Sheffield, South Yorkshire, United Kingdom<br />

1295. Method for High Spatial Resolution of Proximal Stations in 3D Time-Resolved Fluoroscopically-Triggered Bolus<br />

Chase MRA<br />

Thomas W. Polley 1 , Casey P. Johnson 2 , Stephen J. Riederer 2<br />

1 Electrical Engineering, Brigham Young University, Provo, UT, United States; 2 MR Research Laboratory, Mayo Clinic, Rochester,<br />

MN, United States<br />

1296. Assessment of Glenn-Fontan Shunts in Congenital Heart Disease using Low-Dose Time-Resolved & Multi-Phase<br />

High Spatial Resolution CEMRA<br />

Moritz Wagner 1,2 , Saeed Mirsadraee 3 , Pierangelo Renella 4 , Gary M. Satou 4 , Jamil Aboulhosn 4 , John S. Child 4 , Carissa<br />

Fonseca 2 , Roya Saleh 2 , Paul Finn 2<br />

1 Radiology, Charite - University Hospital, Berlin, Germany; 2 Department of Radiological Sciences, David Geffen School of Medicine,<br />

University of California, Los Angeles, CA, United States; 3 Clinical Research Imaging Centre, University of Edinburgh, Edinburg,<br />

United Kingdom; 4 Division of Pediatric Cardiology, Mattel Children's Hospital, University of California, Los Angeles, CA, United<br />

States<br />

1297. In Vivo Fluorine-19 MR Angiography in a Mouse Model<br />

Ruud B. van Heeswijk 1,2 , Yves Pilloud 2,3 , Ulrich Flögel 4 , Juerg Schwitter 5 , Matthias Stuber 1,2<br />

1 Department of Radiology, Centre Hospitalier Universitaire Vaudois & University of Lausanne, Lausanne, VD, Switzerland; 2 Center<br />

for Biomedical Imaging (CIBM), Lausanne, VD, Switzerland; 3 Laboratory for Functional & Metabolic Imaging (LIFMET), Ecole<br />

Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland; 4 Institute for Cardiovascular Physiology, Heinrich Heine<br />

University, Düsseldorf, Germany; 5 Center for Cardiac Magnetic Resonance & Cardiology Service, Centre Hospitalier Universitaire<br />

Vaudois, Lausanne, Switzerland<br />

1298. A Universal Timing Strategy for Moving Table Peripheral MRA<br />

Jeffrey Harold Maki 1,2 , George Rachid Oliveira 2 , Gregory J. Wilson 3<br />

1 Radiology, Puget Sound VAHCS, Seattle, WA, United States; 2 Radiology, University of Washington, Seattle, WA, United States;<br />

3 MR Clinical Science, Philips Healthcare, Cleveland, OH, United States<br />

1299. Accuracy of MRI for <strong>the</strong> Assessment of <strong>the</strong> Geometry of Thoracic Stent Grafts<br />

Volker Rasche 1 , Stephan Trumpp 1,2 , Alexander Oberhuber 2 , Nico Merkle 1 , Karl Heinz Orend 2 , Martin Hoffmann 3 ,<br />

Wolfgang Rottbauer 1 , Axel Bornstedt 1<br />

1 Internal Medicine II, University Hospital Ulm, Ulm, Germany; 2 Thorax & Vascular Surgery, University Hospital Ulm, Ulm,<br />

Germany; 3 Radiology, University Hospital Ulm, Ulm, Germany<br />

1300. Improved Spatial & Temporal Resolution using Parallel Imaging & SOS Trajectory for HYPR Reconstruction<br />

Lauren Ashley Keith 1 , Kang Wang 1 , James H. Holmes 2 , Philip Beatty 2 , Frank Korosec 3<br />

1 Medical Physics, UW - Madison, Madison, WI, United States; 2 Global Applied Science Laboratory, GE Healthcare; 3 Radiology, UW<br />

- Madison, Madison, WI, United States<br />

1301. Time-Resolved Calf-Foot Bolus Chase MRA with Sub-Millimeter Resolution & Real-Time Table Motion<br />

Triggering using 3D MR Fluoroscopy<br />

Casey P. Johnson 1 , Eric A. Borisch 1 , James F. Glockner 1 , Petrice M. Mostardi 1 , Thomas W. Polley 2 , Paul T. Weavers 1 ,<br />

Phillip M. Young 1 , Stephen J. Riederer 1<br />

1 MR Research Laboratory, Mayo Clinic, Rochester, MN, United States; 2 Electrical Engineering, Brigham Young University, Provo,<br />

UT, United States<br />

158

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!