Installation Guide<br />
T942C- and T942C/2 Central Unit<br />
TD 91684GB<br />
Handook page<br />
9/128<br />
Opening the Housing from the Front<br />
If the housing has to be mounted without sufficient space below it, the cut-out holes in<br />
the housing lid should be opened to facilitate maintenance.<br />
Cut Out<br />
Cut Out<br />
Figure 5. Cut outs for opening the cover.<br />
When the holes are opened, a screwdriver can be used to open the lid. Apply a slight<br />
downward pressure (1), then gently lever the screwdriver downwards (2), the clips which<br />
hold the lid will then be released and the cover can be removed (3).<br />
1<br />
2<br />
3<br />
Figure 6. Removing the cover.<br />
To replace the circuit board, see 1.3.19 Circuit Board Replacement on page 20.<br />
2003-01-08 / Rev.C<br />
7