Handook page<br />
16/128<br />
Installation Guide<br />
T942C- and T942C/2 Central Unit<br />
TD 91684GB<br />
1.3.10 Connection of Reference Module in a FL-System (used only in paging<br />
systems)<br />
Connect a twisted-pair from connector J12 screw 6 and 2 to Reference Module T938RM<br />
connector J04 screw 5 and 6, respectively (polarized!).<br />
T942C<br />
GND 6<br />
J12<br />
OUT1 (CODE1) 2<br />
1<br />
T938RM<br />
REF ON 6<br />
GND 5<br />
J04<br />
Figure 17. Connection of the Reference Module to the Central Unit.<br />
Note: The digital outputs must be provided with supply voltage, see 1.3.9 Connection of<br />
Supply Voltage on page 13.<br />
1.3.11 Connection of absent indication from teleCOURIER 800 System Charging<br />
Rack T862<br />
Connect absent indication from Charging Rack T862 connector A screw 3 and 4, to<br />
T942C connector J11 screw 1 and 5. (See also drawing no. OE 8578-4A).<br />
T942C J11<br />
6<br />
IN4 (ABS) 5<br />
+12V 1<br />
RE1<br />
T862<br />
Connector A<br />
3<br />
4<br />
Figure 18. Connection from Charging Rack to the Central Unit<br />
Note: The digital inputs must be provided with supply voltage, see 1.3.9 Connection of<br />
Supply Voltage on page 13.<br />
1.3.12 Connection of Monitor Input<br />
In some cases it may be desirable to prevent the paging transmitters from transmitting,<br />
e.g. when a carrier wave is already in the air.<br />
Monitor input can be used to prevent the Central Unit both from activating the output<br />
stage in the transmitters and from sending the transmitter code to them when a carrier<br />
wave is in the air.<br />
2003-01-08 / Rev.C<br />