Handook page<br />

50/128<br />

Installation Guide<br />

PBX Interface T942PX<br />

TD 91012GB<br />

PBX Interface T942PX - Installation Guide<br />

T942PX is an interface unit between the teleCOURIER <strong>900</strong> paging system and a telephone exchange,<br />

PBX (Private Branch Exchange). In some cases the T942PX is used to connect a telephone as control<br />

instrument. The PX unit may be connected to an extension or to a trunk line. When connected to a<br />

trunk line it detects and generates both dial pulses and DTMF tone signals. When connected to an<br />

extension it detects and generates DTMF tone signals and generates dial pulses.<br />

E & M signaling according to ”ESPA standard interface recommendation 4.4.3” is also possible. If<br />

speech is used in the system, speech module T941SM is included.<br />

A FLASH PROM in T942PX enables remote programming of the program and parameters.<br />

Note: T942PX is not intended for connection to public telephone networks.<br />

1. General<br />

Supply voltage: 12,5 Vdc ± 10%<br />

Current consumption: Max 0,5 A<br />

Delivery includes:<br />

• T942PX<br />

• Modular bus cabling<br />

• If the T942PX is to be used in a speech installation,<br />

speech module T941SM is mounted on the<br />

T942PX PC board and installation guide<br />

TD 90648GB is included in the delivery.<br />

56,5<br />

Dimensions (H x W x D)<br />

275 x 130 x 60 mm<br />

112<br />

It is possible to order from your dealer package<br />

T942PX-2 art. no 541175. In addition to the above<br />

the delivery includes the following items:<br />

• Power supply Mascot 8311, 42 Vac<br />

• Telephone wall socket<br />

• Telephone (Respons)<br />

188,5<br />

9 9<br />

275<br />

Tools etc. required:<br />

• 2 mm drill<br />

• Screwdriver<br />

• Cutting pliers<br />

• Screws for installation<br />

• Multimeter<br />

• (Oscilloscope)<br />

65<br />

130<br />

Note:<br />

To facilitate service after the unit is installed,<br />

we recommend a free space of about 50 mm<br />

above and 150 mm below the unit.<br />

2<br />

2. Installation<br />

T942PX should be placed in a dry environment with<br />

a temperature of 0 to +40ºC. The unit can be<br />

connected together with other units in the<br />

teleCOURIER <strong>900</strong> system, either via modular bus<br />

cabling or via twisted-pairs (see points 8, 9, and 10).<br />

To replace the PC board, see point 18.<br />

The second drawing at left shows dimensions for<br />

installing the T942PX.<br />

1<br />

1<br />

Use a screwdriver or similar to release the cover by<br />

applying a light pressure to the two snap-catches (1)<br />

and remove the cover (2).<br />