Specifications<br />
Specifications Protos CONDI 3400-051<br />
–––––––––––––––––––––––––––– l ––––––––––––––––––––––––––––––––––––––––––––––<br />
CondI input<br />
For electrodeless sensors<br />
(EEx ia IIC)<br />
SE 655, SE 656 (and others)<br />
Measurement range<br />
(SE 655 / SE 656)<br />
0000 µS/cm ... 1999 mS/cm, resolution 1 µS/cm<br />
Concentration<br />
0.0 ... 100.0 % by wt<br />
Salinity<br />
0.0 ... 45.0 g g/kg (0 to 35 °C)<br />
Response time (T90)<br />
< 0.5 s<br />
Measurement error **<br />
< 0.5% meas. val. + 2 µS/cm<br />
Permissible cable length max. 20 m<br />
l –––––––––––––––––––––––––––– l ––––––––––––––––––––––––––––––––––––––––––––––<br />
Temperature<br />
Without<br />
compensation *<br />
Linear characteristic 00.00 ... 19.99 %/K<br />
(reference temp user-defined)<br />
NLF nat. waters to EN 27888<br />
(Reference temp 25 °C)<br />
l –––––––––––––––––––––––––––– l ––––––––––––––––––––––––––––––––––––––––––––––<br />
Concentration<br />
determination * HNO3 0 ... 30 % by wt –20 ... +50°C<br />
35 ... 96 % by wt –20 ... +50°C<br />
HCl 0 ... 18 % by wt –20 ... +50°C<br />
22 ... 39 % by wt –20 ... +50°C<br />
H2SO4 0 ... 30 % by wt –17.8 ... +110°C<br />
32 ... 84 % by wt –17.8 ... +115.6°C<br />
92 ... 99 % by wt –17.8 ... +115.6°C<br />
NaOH 0 ... 14 % by wt 0 ... +100°C<br />
18 ... 50 % by wt 0 ... +100°C<br />
NaCl 0 ... 26 % by wt 0 ... +60°C<br />
User-defined concentration chart (5x5x5 values)<br />
l –––––––––––––––––––––––––––– l ––––––––––––––––––––––––––––––––––––––––––––––<br />
Sensor monitoring * Sensocheck, monitoring of primary and its lines for<br />
short circuit and of secondary and its lines for open circuit,<br />
SensoLoop<br />
Monitoring via Sensocheck loop<br />
70<br />