order to prevent possible measuring errors due to insufficient<br />

transient response time.<br />

(17) 5dB/Div.<br />

Py pushing the 5 dB/Div. button, the vertical scale is set to 5 dB/<br />

Div. The respective LED will then be lit. To enter again in 10 dB/<br />

Div. mode, push 5 dB/Div. again.<br />

(18) RBW (Resolution Bandwidth):<br />

The instrument is equipped with resolution filters of 9kHz, 120kHz,<br />

and 400kHz, which can be selected via the „RBW“ buttons. The<br />

respective LED will indicate which bandwidth is selected.<br />

Remark:<br />

A maximum measuring bandwidth and the Max.HLD function<br />

should be selected for pulsed signals.<br />

(19) VBW-Video Filter:<br />

The Video Filter has the purpose of reducing video and noise<br />

bandwidth and therefore reducing noise distribution. When<br />

measuring low level values, which are situated within the regular<br />

noise level, the Video Filter (low pass) can be used to reduce the<br />

noise level. This allows for the detection of even small signals<br />

which might otherwise not be visible.<br />

Remarks:<br />

Please note that if frequency range (SPAN) is too high and Video<br />

Filter is active, amplitude readings might be wrong (too small)<br />