EMC32 / AMS32 V8.52 Release Note - Rohde & Schwarz
EMC32 / AMS32 V8.52 Release Note - Rohde & Schwarz
EMC32 / AMS32 V8.52 Release Note - Rohde & Schwarz
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>EMC32</strong>-K1 Automotive / MIL<br />
6 <strong>EMC32</strong>-K1 Automotive / MIL<br />
6.1 Extensions<br />
●<br />
●<br />
Pulse Measurement with NRP-Z81: extended trigger and time gate settings<br />
o NRP-Z81 (used with the NRP main frame) in the settings dialog now provides the trigger<br />
and time gate settings for pulse measurement: Gate Start Delay after Trigger, Gate Start in<br />
% of Pulse Length and Gate Length in % of Pulse Length.<br />
Level on Sensor with Power Limitation on the Transducer Forward Power column of a<br />
Reference Calibration file<br />
o NOTE:<br />
The forward power level in the selected Reference Calibration Table is not adapted due to a<br />
different test level of this test compared to the calibration test level of this table !<br />
Example: if the EUT test is done with 200 mA test current, also the corresponding reference<br />
calibration has to be executed with the same current.<br />
7 <strong>EMC32</strong>-K2 Wireless Section<br />
7.1 Extensions<br />
●<br />
●<br />
ABT measurement: support marker for slave trace<br />
o In an EUT monitoring channel graphics showing also a slave trace from another monitoring<br />
channel, not only the trace of the master channel has a marker. In the audio channel both<br />
the DL und UL audio level are shown and both traces can show a marker.<br />
ABT Measurement: Write currently used ABT reference values into test protocol file<br />
o The currently used UL and DL reference values are stored in the protocol.txt of the System<br />
subfolder of the test.<br />
7.2 Improvements<br />
●<br />
ABT Calibration: audio codec of network simulator (CMU) for the current mobile phone<br />
band is configured by <strong>EMC32</strong> before the audio calibration is started<br />
o When using the communication analyzer as audio generator and analyzer, too, then the<br />
setup of the network simulator audio codecs was not performed. This has been corrected.<br />
8 <strong>EMC32</strong>-K4 EMS Auto Test<br />
8.1 Extensions<br />
●<br />
FU Calibration: new option allows to optionally copy the field uniformity evaluation result<br />
reference calibration file to another folder in the Reference Calibration main folder<br />
<strong>Rohde</strong> & <strong>Schwarz</strong> 8