19.04.2014 Views

EMC32 / AMS32 V8.52 Release Note - Rohde & Schwarz

EMC32 / AMS32 V8.52 Release Note - Rohde & Schwarz

EMC32 / AMS32 V8.52 Release Note - Rohde & Schwarz

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EMC32</strong>-K10 EMI Auto Test<br />

10 <strong>EMC32</strong>-K10 EMI Auto Test<br />

10.1 Extensions<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

MIL-STD 461C Tests support Antenna Polarizations<br />

o The EMI auto tests for MIL-STD 461 C (with optional NB/BB discrimination) as well as for<br />

MIL-STD 461 D/E/F now enable to maximize over both antenna polarizations (radiated<br />

emissions tests with antennas only).<br />

Force a receiver preset between test phases<br />

o Because of the many optimizations concerning the programming of the receivers, in an EMI<br />

AT only at the start of a test a preset will occur. The many mode changes and parameter<br />

changes during an EMI AT might make a receiver unstable. Therefore a receiver preset<br />

occurs before each test phase:<br />

- before preview meas.<br />

- before zoom1 meas.<br />

- before max. meas.<br />

- before zoom2/adjustment/finall meas.<br />

EMI Auto Test Editor: enable to alternatively start with hor. Polarization<br />

o In the EMI autotest editor: with Preview > Measurements Accessories > Polarization an<br />

alternatively start with hor./vert. Polarization can be chosen.<br />

Online help<br />

o New flow charts showing Auto Test are added to the online help.<br />

Interactive Data Reduction for Final Measurement with final results from other tests<br />

o It is possible to set the parameter "Interactive Data Reduction before the final<br />

measurement" in the limit lines dialog when the data reduction subdialog is disabled due to<br />

starting the test without preview measurements but with final results from another test.<br />

NSA Measurement<br />

o User messages for repetition of the reference measurement improved.<br />

10.2 Improvements<br />

●<br />

●<br />

Editor Zoom Measurement: doesn't allow to activate a zoom template without selecting<br />

template name<br />

o The EMI AT editor does not allow to save the following setting: activate a zoom scan /<br />

sweep template but with no selected template.<br />

Turn device out of property limits<br />

o<br />

It is now possible to generate a new test if the position of the turn device is outside the<br />

device properties limits.<br />

<strong>Rohde</strong> & <strong>Schwarz</strong> 13