plc advanced functions - 16.5<br />

A<br />

FFL<br />

source I:001<br />

FIFO N7:0<br />

<strong>Control</strong> R6:0<br />

length 5<br />

position 0<br />

B<br />

FFU<br />

FIFO N7:0<br />

destination O:003<br />

<strong>Control</strong> R6:0<br />

length 5<br />

position 0<br />

Figure 16.4<br />

FIFO Stack Instructions<br />

The LIFO stack comm<strong>and</strong>s are shown in Figure 16.5. As values are loaded on the<br />

stack the will be added sequentially N7:0, N7:1, N7:2, N7:3 then N7:4. When values are<br />

unloaded they will be taken from the last loaded position, so if the stack is full the value of<br />

N7:4 will be removed first.<br />

A<br />

B<br />

LFL<br />

source I:001<br />

LIFO N7:0<br />

<strong>Control</strong> R6:0<br />

length 5<br />

position 0<br />

LFU<br />

LIFO N7:0<br />

destination O:003<br />

<strong>Control</strong> R6:0<br />

length 5<br />

position 0<br />

Figure 16.5<br />

LIFO Stack Comm<strong>and</strong>s