plc function ref - 34.28<br />

FFL, FFU, LFL, LFU - FiFo Load, FiFo Unload, LiFo Load, LiFo Unload<br />

Description:<br />

Status Bits:<br />

A<br />

B<br />

FFL<br />

FIFO LOAD<br />

Source<br />

FIFO<br />

<strong>Control</strong><br />

Length<br />

N7:0<br />

N7:10<br />

R6:0<br />

10<br />

Stack instructions will take integer words <strong>and</strong> store them, <strong>and</strong> then allow<br />

later retrieval. The load instructions will store a value on the stack on a<br />

false to true input change. The Unload instructions will remove a<br />

value from that stack <strong>and</strong> store it in the Dest location. A Last On First<br />

Off stack will return the last value pushed on. A First On First Off<br />

stack will give the oldest value on the stack. If an attempt to load more<br />

than the stack length, the values will be ignored. The instructions<br />

available are:<br />

FFL - FIFO stack load<br />

FFU - FIFO stack unload<br />

LFL - LIFO stack load<br />

LFU - LIFO stack unload<br />

EN<br />

DN<br />

ER<br />

UL<br />

Registers: none<br />

Available on: Micrologix, PLC-5<br />

Position 0<br />

FFU<br />

FIFO UNLOAD<br />

FIFO N7:10<br />

Dest<br />

N7:11<br />

<strong>Control</strong> R6:0<br />

Length 10<br />

Position 0<br />

Enable - is on when the input to the function is on<br />

Done - is on when the shift operation is complete<br />

Error - indicates when an error has occurred<br />

Unload - the unloaded value is stored in this bit