plc advanced functions - 16.31<br />

16.9 PRACTICE PROBLEM SOLUTIONS<br />

1.<br />

T4:0/DN<br />

T4:0/DN<br />

B3:0 = 0000 0000 0000 1111 (grn EW)<br />

B3:1 = 0000 0000 0001 0000 (yel EW)<br />

B3:2 = 0000 0011 1110 0000 (red EW)<br />

B3:3 = 0000 0011 1100 0000 (grn NS)<br />

B3:4 = 0000 0000 0010 0000 (yel NS)<br />

B3:5 = 0000 0000 0001 1111 (red NS)<br />

TON<br />

Timer T4:0<br />

Delay 4s<br />

BSR<br />

File B3:0<br />

<strong>Control</strong> R6:0<br />

Bit address R6:0/UL<br />

Length 10<br />

BSR<br />

File B3:1<br />

<strong>Control</strong> R6:1<br />

Bit address R6:1/UL<br />

Length 10<br />

BSR<br />

File B3:2<br />

<strong>Control</strong> R6:2<br />

Bit address R6:2/UL<br />

Length 10<br />

BSR<br />

File B3:3<br />

<strong>Control</strong> R6:3<br />

Bit address R6:3/UL<br />

Length 10<br />

BSR<br />

File B3:4<br />

<strong>Control</strong> R6:4<br />

Bit address R6:4/UL<br />

Length 10<br />

BSR<br />

File B3:5<br />

<strong>Control</strong> R6:5<br />

Bit address R6:5/UL<br />

Length 10