6.1.3 Compressors<br />

Challenge OMRON <strong>SX</strong>-V solution Menu<br />

High start currents require larger fuses and cables.<br />

Cause stress on equipment and higher energy cost.<br />

Compressor is damaged when cooling media<br />

enters the compressor screw.<br />

Pressure is higher than needed, causing leaks,<br />

stress on the equipment and excessive air use.<br />

Motor runs at same speed when no air is compressed.<br />

Energy is lost and equipment stressed.<br />

Process inefficiency and energy wasted due to e.g.<br />

the compressor idling.<br />

Torque control reduces start current. Same fuses<br />

can be used as those required for the motor.<br />

Overload situation is quickly detected and safety<br />

stop can be activated to avoid breakdown.<br />

Load Curve Protection function detects deviation.<br />

Warning is sent or safety stop activated.<br />

PID continuously adapts to the level required.<br />

Sleep function activated when none is needed.<br />

Load Curve Protection quickly detects deviation.<br />

Warning is sent or safety stop activated.<br />

331– 336, 351<br />

411–41A<br />

411–419, 41C1–41C9<br />

320, 380, 342, 354<br />

411–419, 41C1–41C9<br />

6.1.4 Blowers<br />

Challenge OMRON <strong>SX</strong>-V solution Menu<br />

High start currents require larger fuses and cables.<br />

Cause stress on equipment and higher energy cost.<br />

Difficult to compensate for pressure fluctuations.<br />

Wasted energy and risk of production stop.<br />

Motor runs at same speed despite varying<br />

demands. Energy is lost and equipment stressed.<br />

Process inefficiency due to e.g. a broken damper, a<br />

valve not fully opened or a worn belt.<br />

Torque control reduces start current. Same fuses<br />

can be used as those required for the motor.<br />

PID function continuously adapts pressure to the<br />

level required.<br />

PID continuously adapts air flow to level required.<br />

Sleep function activated when none is needed.<br />

Load Curve Protection quickly detects deviation.<br />

Warning is sent or safety stop activated.<br />

331–336, 351<br />

320, 380<br />

320, 380, 342, 354<br />

411–419, 41C1–41C9<br />

34 Applications <strong>Omron</strong> <strong>SX</strong> <strong>inverter</strong> <strong>manual</strong>