List of Tables<br />
3.1 Evaluation approaches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
3.2 Partial diagnosis look-up table of the Power Supply system for single faults (startup =<br />
true) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />
3.3 Input matrix for data analysis of the example fault scenario . . . . . . . . . . . . . . . 29<br />
3.4 Evaluation approaches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
4.1 Mode catalog of the 4-inverter model, with x=1 <strong>and</strong> y=0. . . . . . . . . . . . . . . . . 45<br />
4.2 Partial LUT for a strong model of the Power Supply system for single faults (startup =<br />
true) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
5.1 Example of a log entry (when error 11 occurs). . . . . . . . . . . . . . . . . . . . . . 52<br />
5.2 Components that are excluded from the target system. . . . . . . . . . . . . . . . . . . 53<br />
5.3 Components that are included in the target system, with their health variables, <strong>and</strong> associated<br />
a priori failure probabilities. . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
5.4 Fault scenarios, <strong>and</strong> their adjudged diagnoses. . . . . . . . . . . . . . . . . . . . . . . 55<br />
5.5 Partial diagnosis look-up table of the Beam Propeller Movement for single faults . . . 57<br />
5.6 Discretization of the system data of fault scenario 1 till 11 to domain M. . . . . . . . . 63<br />
5.7 Partial diagnosis Look-Up Table of the Beam Propeller Movement for single faults . . 64<br />
5.8 Some additional measurements for fault scenarios in fault category C1 (current error) . 65<br />
5.9 Some additional measurements for fault scenarios in fault category C2 (speed error) . . 67<br />
5.10 Some additional measurements for fault scenarios in fault category C3 (unjustified position<br />
error) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />
5.11 Some additional measurements for fault scenarios in fault category C4 (pos. val. error) 67<br />
5.12 Entropy gain of 5 arbitrarily chosen additional sensor set-ups. . . . . . . . . . . . . . . 67<br />
5.13 5 additional fault scenarios, of which adjudged broken components are known. . . . . 68<br />
B.1 The meaning of the system data that can be found in an error 11 entry. . . . . . . . . . 86<br />
B.2 All fault scenarios, <strong>and</strong> their system data. . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
ix