Planning Guide<br />

<strong>Glandless</strong> <strong>Pumps</strong> (General)<br />

Sound pressure level<br />

The construction of the glandless pumps is the reason for their lownoise<br />

operation. Its air-borne noise values with measuring-surface<br />

sound pressure level Lp (A) [dB] depend on the motor power output<br />

and are determined under normal operating conditions.<br />

[dB] 60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

Fig.:<br />

0<br />

10 20 50 100 200 500 1000 2000 3000 5000<br />

W<br />

Rate motor output P2<br />

Lp (A) [dB], 2-pole standard pumps (max. 2900 1/min.) and Stratos series<br />

Lp (A) [dB], 4-pole standard pumps (max. 1450 1/min.) and TOP-E series<br />

Sound pressure level of glandless pumps, determined in accordance with<br />

DIN EN ISO 3745<br />

Heat insulation with heating applications<br />

All Wilo-Stratos/Stratos-Z, Wilo-TOP-E/-S/-Z/-D and Stratos <strong>ECO</strong><br />

single-head pumps are standard-equipped with thermal insulation<br />

shells for the prevention of thermal losses at the pump housing.<br />

Material: EPP, polypropylene foam<br />

Thermal conductivity: 0.04 W/m K in accordance with DIN 52612<br />

Flammability: Class B2 in accordance with DIN 4102; FMVSS 302<br />

When insulating the pump on-site, care must be taken to cover the<br />

pump up to the top edge of the pump housing only (the motor must<br />

be left uncovered).<br />

Thermal insulation for air-conditioning/cooling applications<br />

If pumps from the following series:<br />

- Stratos, Stratos-D, Stratos-Z<br />

-TOP-S/-SD<br />

-TOP-D<br />

-TOP-Z<br />

-TOP-RL<br />

-SE/SE-TW<br />

are utilised in air-conditioning/cooling applications, no vapour-proof<br />

insulation is permitted to cover the drain labyrinth between the pump<br />

housing and the motor. This is to ensure that any condensate having<br />

possibly accumulated in the motor can drain off freely through the<br />

condensate drain openings in the motor housing.<br />

The Wilo-ClimaForm vapour-proof insulation that is obtainable as an<br />

accessory for the Stratos, TOP-S, TOP-RL and SE series for insulating<br />

pump housings in cold water applications guarantees this automatically,<br />

thanks to its specific construction.<br />

Quality and safety marks<br />

For pump types:<br />

Star-E 25/ ..., -E 30/ ...,<br />

Stratos <strong>ECO</strong><br />

Star-RS 25/ ..., -RS 30/ ...,<br />

RSD 30/ ..., Star-Z 20/1, -Z 25/6, Star-ZE 25/ ...,<br />

Rp 25/60-2<br />

Certificate of conformity/acceptance test certificate<br />

Available upon request at additional charge for all glandless circulating<br />

pumps of the series<br />

- Stratos, Stratos-D, Stratos-Z<br />

-TOP-E/-ED<br />

-TOP-S/-SD<br />

-TOP-D<br />

-TOP-Z<br />

-TOP-RL<br />

- P/RP (not RP 25/60-2)<br />

-DOP<br />

- SE/SE-TW<br />

- Certificate of conformity 2.1<br />

Contents: Certification that the product supplied conforms to the<br />

order, without details of test results.<br />

- Certificate of conformity 2.2<br />

Contents: Certification that the product supplied conforms to the<br />

order, with details of series test results.<br />

- Acceptance test certificate 3.1B<br />

Contents: Certification that the product supplied conforms to the<br />

order, with details of test results actually measured on the product.<br />

The required test procedure and scope must be specified with the<br />

order.<br />

Wilo-ClimaForm:<br />

- Water vapour diffusion resistance µ 7000<br />

- Normal flammability, in accordance with DIN 4102-B2, Part 1<br />

- Quality-monitored in accordance with DIN 18200<br />

10 Subject to change without prior notice 09/2006 WILO AG