Switchgears and Control Devices<br />

Switchgears<br />

Device allocation, equipment Wilo-S2R 3D/SD<br />

Device allocation<br />

Twin-head pump or 2 x individual pump<br />

Main/standby or peak-load operation<br />

Time-sensitive and/or<br />

Device equipment<br />

Pump connecting cable<br />

provided by<br />

customer<br />

provided by<br />

customer<br />

provided by<br />

customer<br />

provided by<br />

customer<br />

provided by<br />

customer<br />

provided by<br />

customer<br />

Activation type direct Y/ Y/ Y/ Y/ Y/<br />

Fitted temperature sensors each with 5 m<br />

cable 3) • 2 • 2 • 2 • 2 • 2 • 2<br />

Fitted control cable 3 m/5m 3) • • • • • • • • • • • •<br />

Fault pump switchover • • • • • •<br />

Twin-head pump operation switchover<br />

switching<br />

Twin-head pump addition switching for<br />

peak-load operation<br />

Integrated full motor protection tripping<br />

(starting with 11 kW thermistor)<br />

Excess current draw fault trip • • •<br />

Setting range, motor protection switch (1 - 10) A (5.2 - 7.5) A (9.0 - 13.0) A<br />

• • • • • •<br />

• • • • • •<br />

• • • •<br />

Automatic reactivation after power failure 2) • • • • • •<br />

Potential-free contact for external run signal • o o o o o<br />

Potential-free contact for external fault signal • • • • • •<br />

Potential-free contacts for individual run and<br />

fault signals<br />

Terminals for power supply to an external<br />

signal transmitter<br />

Differential pressure-dependent p<br />

o o o o o o<br />

• • • • • •<br />

Terminals for external ON/OFF control • • • • • •<br />

Protection class 1) IP 41 IP 54 IP 54 IP 54 IP 54 IP 54<br />

• Standard version<br />

o Special version or supplementary equipment (at additional charge)<br />

1) Protection class of the entire switch cabinet applies to switch cabinet installation<br />

2) Clock setting must be corrected in event of a power failure lasting more than 15 minutes (standard version)<br />

3) Included in the scope of delivery of the auxiliary transmitter or the auxiliary module<br />

Temperature-dependent +T<br />

Differential temperature-dependent T<br />

Differential pressure-dependent p<br />

Temperature-dependent +T<br />

Switching device S2R 3D SD 5.5 SD 9 SD 18.5 SD 30 SD 37<br />

Auxiliary signal transmitter<br />

DDM<br />

o<br />

TF<br />

o<br />

DTS<br />

o<br />

DDM<br />

o<br />

TF<br />

o<br />

Differential temperature-dependent T<br />

DTS<br />

o<br />

Differential pressure-dependent p<br />

DDM<br />

o<br />

Temperature-dependent +T<br />

TF<br />

o<br />

Differential temperature-dependent T<br />

DTS<br />

o<br />

Differential pressure-dependent p<br />

DDM<br />

o<br />

Temperature-dependent +T<br />

TF<br />

o<br />

Differential temperature-dependent T<br />

DTS<br />

o<br />

Differential pressure-dependent p<br />

DDM<br />

o<br />

Temperature-dependent +T<br />

TF<br />

o<br />

Differential temperature-dependent T<br />

DTS<br />

o<br />

Differential pressure-dependent p<br />

DDM<br />

o<br />

Temperature-dependent +T<br />

TF<br />

o<br />

Differential temperature-dependent T<br />

DTS<br />

o<br />

Heating, Air-conditioning,<br />

Cooling<br />

Potable water circulation<br />

Solar thermal<br />

Service/Accessories, Systems<br />

Switchgears and Control Devices<br />

Pump Management Systems<br />

Wilo Catalogue A1 - Circulating pumps in glandless design<br />

385