25.09.2014 Views

Glandless Pumps - THERMO-ECO-ENGINEERING úvod

Glandless Pumps - THERMO-ECO-ENGINEERING úvod

Glandless Pumps - THERMO-ECO-ENGINEERING úvod

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Potable water circulation<br />

High-efficiency pumps (single-head pumps)<br />

Equipment/Function Stratos-<strong>ECO</strong>-Z/<strong>ECO</strong>-Z BMS, Stratos-Z<br />

Wilo-Stratos <strong>ECO</strong>-Z<br />

Wilo-Stratos-Z<br />

Operating modes<br />

Speed-stage switching – –<br />

Manual control mode (n=constant)<br />

p-c for constant differential pressure<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

p-v for variable differential pressure • •<br />

p-T for temperature-prompted differential pressure – •<br />

Manual functions<br />

Setting the operating mode<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

Setting the differential-pressure setpoint • •<br />

Setting to “Autopilot” (automatic setback mode) • •<br />

Setting the pump to ON/OFF<br />

Setting the speed (manual setting mode)<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

Setting the speed stages – –<br />

Automatic functions<br />

Stepless power adjustment depending on the<br />

operating mode<br />

• •<br />

“Autopilot” automatic setback mode • •<br />

Deblocking function • •<br />

Soft start • •<br />

Safety control • –<br />

Full motor protection with integrated trip electronics – •<br />

External control functions<br />

Control input “Overriding Off”<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Possible with Stratos IF-Modul (accessory)<br />

Control input “Overriding Min” – •<br />

Possible with Stratos IF-Modul (accessory)<br />

Control input “Analogue in 0- 10 V”<br />

(remote speed adjustment)<br />

Control input “Analogue in 0- 10 V”<br />

(remote setpoint adjustment)<br />

Signal and display functions<br />

Single/collective fault signal<br />

(potential-free NC contact)<br />

Collective fault signal (potential-free NC contact)<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

•<br />

Possible with Stratos IF-Modul (accessory)<br />

•<br />

Possible with Stratos IF-Modul (accessory)<br />

– –<br />

•<br />

(only Stratos <strong>ECO</strong>-Z...-BMS)<br />

Individual run signal (potential-free NO contact) – •<br />

Possible with Stratos IF-Modul (accessory)<br />

• = available, – = not available<br />

•<br />

248 Subject to change without prior notice 09/2006 WILO AG