Switchgears and Control Devices<br />

Planning Guide<br />

Selection recommendation (twin-head pumps or 2 single-head pumps)<br />

Function<br />

Twin-head<br />

pumps<br />

Pump type<br />

2 Single-head<br />

pumps<br />

– 2 x TOP-RL 25/7.5<br />

– 2 x TOP-RL 30/4 6<br />

– 2 x TOP-RL 30/6.5 6<br />

– 2 x TOP-RL 30/7.5 6<br />

– 2 x TOP-RL 40/4 – – – – –<br />

2 x AS 08 +<br />

SK 613<br />

–<br />

6<br />

– 2 x SE 110-N 6<br />

SE 125-N-TW 2 x SE 125-N 6<br />

SE 150-N-TW 2 x SE 150-N 6<br />

SE 200-N-TW 2 x SE 200-N 6<br />

– 2 x RP 25/60-2 – – – – –<br />

– 2 x RP 25/80 r S4R 2.5 D T/T MOD + sensor p MOD 6<br />

– 2 x RP 25/100 r S4R 2.5 D T/T MOD + sensor p MOD 6<br />

– – –<br />

2 x AS 08 +<br />

SK 613<br />

2 x AS 08 +<br />

SK 613<br />

DOP 32/80 r 2 x RP 30/80 r S4R 2.5 D T/T MOD + sensor p MOD 6 – –<br />

– 2 x RP 30/100 r S4R 2.5 D T/T MOD + sensor p MOD 6 2 x AS 08 + 2 x AS 08 + 6<br />

DOP 40/100 r 2 x P 40/100 r S4R 2.5 D T/T MOD + sensor p MOD 6 SK 613 SK 613 6<br />

DOP 40/160 r 2 x P 40/160 r S4R 2.5 D T/T MOD + sensor p MOD 6<br />

2 x AS 08 + 6<br />

–<br />

DOP 50/100 r 2 x P 50/125 r S4R 2.5 D T/T MOD + sensor p MOD 6 SK 613 6<br />

DOP 50/160 r 2 x P 50/160 r S4R 2.5 D T/T MOD + sensor p MOD 10 –<br />

– 2 x P 50/250 r S4R 2.5 D T/T MOD + sensor p MOD 16 –<br />

2 x AS 08 +<br />

SK 613<br />

2 x AS 1.5 +<br />

SK 613<br />

DOP 65/125 r 2 x P 65/125 r S4R 2.5 D T/T MOD + sensor p MOD 6<br />

2 x AS 08 + 6<br />

–<br />

DOP 65/160 r 2 x P 65/160 r S4R 2.5 D T/T MOD + sensor p MOD 10 SK 613 10<br />

– 2 x P 65/250 r S4R 2.5 D T/T MOD + sensor p MOD 16 –<br />

2 x AS 1.5 +<br />

SK 613<br />

DOP 80/125 r 2 x P 80/125 r S4R 2.5 D T/T MOD + sensor p MOD 6<br />

2 x AS 08 + 6<br />

–<br />

DOP 80/160 r 2 x P 80/160 r S4R 2.5 D T/T MOD + sensor p MOD 10 SK 613 10<br />

– 2 x P 80/250 r S4R 2.5 D T/T MOD + sensor p MOD 16 – – –<br />

DOP 100/160 r 2 x P 100/160 r S4R 2.5 D T/T MOD + sensor p MOD 10 –<br />

WA = wall-mounted installation<br />

SE = switch cabinet installation<br />

WA/SE = wall-mounted or switch cabinet installation<br />

DM = three-phase AC motor<br />

EM = single-phase AC motor<br />

Base<br />

unit<br />

Load<br />

module<br />

1) Signal transmitter DDS to be ordered extra (specify measuring range)<br />

4-stage switching<br />

Wilo-SR-System<br />

Time-sensitive plus<br />

(+T/T)<br />

(p)<br />

Signal<br />

transmitter<br />

Load<br />

module<br />

Signal<br />

transmitter<br />

Stepless control<br />

Wilo-AS-System<br />

differential pressure (p)<br />

Basic device<br />

2 x AS 1.5 +<br />

SK 613<br />

Signal<br />

transmitter<br />

DM EM DM<br />

WA/SE DDM WA/SE DDS 1)<br />

6<br />

6<br />

6<br />

16<br />

16<br />

10<br />

Heating, Air-conditioning,<br />

Cooling<br />

Potable water circulation<br />

Solar thermal<br />

Service/Accessories, Systems<br />

Switchgears and Control Devices<br />

Pump Management Systems<br />

Wilo Catalogue A1 - Circulating pumps in glandless design<br />