ACCESSORIES AND DETAILS<br />

BRIDGING REQUIREMENTS FOR K-SERIES JOISTS<br />

Number of Rows of Bridging***<br />

Distances are Span Lengths<br />

(see "Definition of Span" on page 30.)<br />

ERECTION STABILITY SPANS<br />

Section (SJI Spec. Section 6)<br />

Numbers* Depth Span Less Than** 1 Row 2 Rows 3 Rows 4 Rows 5 Rows<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

8 17’<br />

10 21’<br />

12 23’<br />

14 27’<br />

16 29’<br />

12 25’<br />

14 29’<br />

16 30’<br />

18 31’<br />

20 32’<br />

14 29’<br />

16 32’<br />

18 32’<br />

20 34’<br />

22 34’<br />

24 36’<br />

12 25’<br />

16 32’<br />

18 33’<br />

20 34’<br />

22 35’<br />

24 38’<br />

26 38’<br />

14 29’<br />

16 33’<br />

18 35’<br />

20 36’<br />

22 36’<br />

24 39’<br />

26 39’<br />

28 40’<br />

16 33’<br />

18 37’<br />

20 39’<br />

22 40’<br />

24 43’<br />

26 43’<br />

28 43’<br />

30 44’<br />

24 43’<br />

26 44’<br />

28 44’<br />

30 45’<br />

16 33’<br />

18 37’<br />

20 39’<br />

22 40’<br />

24 44’<br />

26 44’<br />

28 45’<br />

30 45’<br />

Up thru 16’ Over 16’ Over 24’<br />

thru 24’ thru 28’<br />

Up thru 17’ Over 17’ thru 25’ Over25’thru32’<br />

Up thru 18’ Over 18’ Over 28’ Over 38’<br />

thru 28’ thru 38’ thru 40’<br />

Up thru 19’ Over 19’ Over 28’ Over 38’<br />

thru 28’ thru 38’ thru 48’<br />

Up thru 19’ Over 19’ Over 29’ Over 39’ Over 50’<br />

thru 29’ thru 39’ thru 50’ thru 52’<br />

Up thru 19’ Over 19’ Over 29’ Over 39’ Over 51’<br />

thru 29’ thru 39’ thru 51’ thru 56’<br />

Up thru 20’ Over 20’ Over 33’ Over 45’ Over 58’<br />

thru 33’ thru 45’ thru 58’ thru 60’<br />

Up thru 20’ Over 20’ Over 33’ Over 45’ Over 58’<br />

thru 33’ thru 45’ thru 58’ thru 60’<br />

Up thru 20’ Over 20’ Over 33’ Over 46’ Over 59’<br />

thru 33’ thru 46’ thru 59’ thru 60’<br />

10<br />

11<br />

12<br />

18 37’<br />

20 41’<br />

22 45’<br />

24 49’<br />

26 49’<br />

28 49’<br />

30 50’<br />

22 45’<br />

30 52’<br />

24 49’<br />

26 53’<br />

28 53’<br />

30 54’<br />

Up thru 20’ Over 20’ Over 37’ Over 51’<br />

thru 37’ thru 51’ thru 60’<br />

Up thru 20’ Over 20’ Over 38’ Over 53’<br />

thru 38’ thru 53’ thru 60’<br />

Up thru 20’ Over 20’ Over 39’ Over 53’<br />

thru 39’ thru 53’ thru 60’<br />

* Last digit(s) of joist designation.<br />

** For spans EQUAL TO OR EXCEEDING that shown above, one of the required rows, nearest mid-span, must be bolted diagonal type. Bolted diagonal<br />

bridging shall be installed and connected BEFORE releasing the hoisting lines. Refer to Specification Section 6 for handling and erection requirements.<br />

*** See SJI Specifications 5.11 for uplift requirement, page 29.<br />

35