3.3.2 7120P/SE10P/5110P/3120P/31S1P Passive Cooling<br />

Solution<br />

For the passive heat sink on the 7120P/SE10P/5110P/3120P/31S1P SKUs, the Intel ®<br />

<strong>Xeon</strong> <strong>Phi</strong> coprocessor thermal & mechanical solution also utilizes a 'fuselage/<br />

supersink' approach. Figure 3-5 illustrates the key components of the passive design.<br />

Figure 3-5<br />

Exploded View of Passive Thermal Solution<br />

As in the active thermal solution, the duct is metallic and performs both structural and<br />

thermal roles. In its 'fuselage' function, the duct provides structural support for the<br />

forces generated by the CPU thermal interface, protects against shock events, and<br />

channels airflow through the card. In its 'supersink' function, the duct contains internal<br />

fins and heat pipes. The internal heat pipes serve to transmit heat from GDDR (both<br />

top- and bottom-side) and VR components to the internal fin banks, diecast blower<br />

frame, and metal fuselage structure where it can be effectively transferred to the<br />

airstream. The passive solution does not have a diecast blower frame as it relies upon<br />

forced airflow from the host system. In place of the blower and frame, an additional fin<br />

bank is added to dissipate waste heat from GDDR and VR components. The fin spacing<br />

of all fin banks as well as of the CPU heat sink fin bank have been optimized for<br />

receiving system-supplied airflow. A backplate stiffener/heat sink is used.<br />

3.3.2.1 System Airflow for 5110P SKUs<br />

In order to ensure adequate cooling of the 5110P SKUs with a 45 o C inlet temperature,<br />

the system must be able to provide 20 ft 3 /min of airflow to the card with 4.3 ft 3 /min on<br />

the secondary side and the remainder on the primary side. The total pressure drop<br />

(assuming a multi-card installation conforming to the PCI Express* mechanical<br />

specification) is 0.21 inch H 2 O at this flow rate.<br />

Note:<br />

For systems with reversed airflow, the corresponding airflow requirement is expected<br />

to be within +/-5% tolerance of the values shown in the following tables.<br />

Document ID Number: 328209 003EN<br />