Figure 3-8 Airflow Requirement vs. Inlet Temperature for the 5110P Card at 245W TDP 1<br />

Card Inlet ( o C) Total Flow (ft^3/min) Primary (ft^3/min) Secondary (ft^3/min) Card dP (inH 2O)<br />

20 12.8 9.9 2.9 0.1<br />

21 13 10 3 0.11<br />

22 13.2 10.2 3 0.11<br />

23 13.5 10.4 3.1 0.11<br />

24 13.7 10.6 3.1 0.12<br />

25 14 10.8 3.2 0.12<br />

26 14.3 11 3.2 0.13<br />

27 14.6 11.3 3.3 0.13<br />

28 14.9 11.5 3.4 0.13<br />

29 15.2 11.8 3.5 0.14<br />

30 15.6 12 3.5 0.15<br />

31 15.9 12.3 3.6 0.15<br />

32 16.3 12.6 3.7 0.16<br />

33 16.7 13 3.8 0.16<br />

34 17.2 13.3 3.9 0.17<br />

35 17.6 13.7 4 0.18<br />

36 18.1 14.1 4.1 0.19<br />

37 18.7 14.5 4.2 0.2<br />

38 19.2 14.9 4.3 0.21<br />

39 19.9 15.4 4.4 0.22<br />

40 20.5 15.9 4.6 0.23<br />

41 21.2 16.5 4.7 0.25<br />

42 22 17.1 4.9 0.26<br />

43 22.9 17.8 5.1 0.28<br />

44 23.8 18.5 5.3 0.3<br />

45 24.9 19.4 5.5 0.33<br />

Notes:<br />

1. Refer to Section 5.1 for note on 5110P TDP.<br />

Document ID Number: 328209 003EN<br />

Intel ® <strong>Xeon</strong> <strong>Phi</strong> <strong>Coprocessor</strong> <strong>Datasheet</strong><br />