Belgian requirements for A1-A4 animal houses<br />
1. Equipment and technical requirements<br />
Specifications<br />
Conta<strong>in</strong>ment level<br />
A1 A2 A3 A4<br />
1 The animalarium is separated from not required required required required<br />
o<strong>the</strong>r work<strong>in</strong>g zones <strong>in</strong> <strong>the</strong> same<br />
build<strong>in</strong>g or is located <strong>in</strong> a separate<br />
build<strong>in</strong>g<br />
2 Entry via an airlock not required recommended required required (with three<br />
compartments)<br />
3 Doors that can be locked required required required required<br />
4 Doors that close automatically not required required required required<br />
5 W<strong>in</strong>dows that cannot be opened not required not required, required required<br />
buth w<strong>in</strong>dows should<br />
(able to withstand<br />
be closed dur<strong>in</strong>g<br />
break<strong>in</strong>g)<br />
experimentation<br />
6 Airtight <strong>laboratory</strong> that enables not required optional required required<br />
decontam<strong>in</strong>ation with a gas<br />
7 Build<strong>in</strong>g designed <strong>in</strong> such a way recommended required required required<br />
that accidental escape of animals<br />
is avoided<br />
8 Observation w<strong>in</strong>dow or equivalent recommended recommended required required<br />
system that enables one to see who<br />
is work<strong>in</strong>g <strong>in</strong> <strong>the</strong> <strong>laboratory</strong><br />
9 Decontam<strong>in</strong>ation facilities for <strong>the</strong> required (s<strong>in</strong>ks) required (s<strong>in</strong>ks) required (s<strong>in</strong>ks near required (s<strong>in</strong>ks and<br />
personnel <strong>the</strong> exit or <strong>in</strong> <strong>the</strong> shower, <strong>the</strong> latter fitted<br />
airlock) shower: with a chemical spr<strong>in</strong>kler<br />
recommended <strong>in</strong> case use is made<br />
of isolation suit fitted<br />
with positive air pressure)<br />
10 S<strong>in</strong>ks that can be operated not required recommended required required<br />
non-manually<br />
11 Coathooks or chang<strong>in</strong>g room for required required required required<br />
<strong>the</strong> protective cloth<strong>in</strong>g<br />
12 Tub<strong>in</strong>g fitted with a system that not required not required recommended required<br />
prevents backward flow of fluids<br />
13 Separate room for <strong>the</strong> stock<strong>in</strong>g of recommended required required required<br />
clean cages, feed and cag<strong>in</strong>g material<br />
14 Surfaces resistant to decontam<strong>in</strong>ants, required required required required<br />
impermeable and easy to clean (cages, benches) (cages, benches, (cages, benches, (cages, benches,<br />
floor) floor, walls, ceil<strong>in</strong>g) floor, walls, ceil<strong>in</strong>g)<br />
15 Facility for <strong>the</strong> wash<strong>in</strong>g of cages required required required required<br />
16 Automous electricity backup system not required not required recommended required<br />
17 Fire alarm (not tak<strong>in</strong>g <strong>in</strong>to account not required not required required required<br />
local fire regulations)<br />
18 System that enables communication not required not required required required (nonwith<br />
<strong>the</strong> outside world<br />
manual operation)<br />
VENTILATION<br />
19 Input airflowsystem separated from not required not required recommended required<br />
adjacent laboratories<br />
20 Extract airflowsystem separated from not required optional recommended required<br />
adjacent laboratories<br />
21 Input and extract airflowsystem not required optional required required<br />
<strong>in</strong>terconnected to prevent accidental<br />
overpressure<br />
22 Input and extract airflowsystem can be not required optional required required<br />
closed us<strong>in</strong>g valves<br />
50<br />
<strong>Biosafety</strong> <strong>in</strong> <strong>the</strong> <strong>laboratory</strong>