Belgian requirements for A1-A4 animal houses<br />

1. Equipment and technical requirements<br />

Specifications<br />

Conta<strong>in</strong>ment level<br />

A1 A2 A3 A4<br />

1 The animalarium is separated from not required required required required<br />

o<strong>the</strong>r work<strong>in</strong>g zones <strong>in</strong> <strong>the</strong> same<br />

build<strong>in</strong>g or is located <strong>in</strong> a separate<br />

build<strong>in</strong>g<br />

2 Entry via an airlock not required recommended required required (with three<br />

compartments)<br />

3 Doors that can be locked required required required required<br />

4 Doors that close automatically not required required required required<br />

5 W<strong>in</strong>dows that cannot be opened not required not required, required required<br />

buth w<strong>in</strong>dows should<br />

(able to withstand<br />

be closed dur<strong>in</strong>g<br />

break<strong>in</strong>g)<br />

experimentation<br />

6 Airtight <strong>laboratory</strong> that enables not required optional required required<br />

decontam<strong>in</strong>ation with a gas<br />

7 Build<strong>in</strong>g designed <strong>in</strong> such a way recommended required required required<br />

that accidental escape of animals<br />

is avoided<br />

8 Observation w<strong>in</strong>dow or equivalent recommended recommended required required<br />

system that enables one to see who<br />

is work<strong>in</strong>g <strong>in</strong> <strong>the</strong> <strong>laboratory</strong><br />

9 Decontam<strong>in</strong>ation facilities for <strong>the</strong> required (s<strong>in</strong>ks) required (s<strong>in</strong>ks) required (s<strong>in</strong>ks near required (s<strong>in</strong>ks and<br />

personnel <strong>the</strong> exit or <strong>in</strong> <strong>the</strong> shower, <strong>the</strong> latter fitted<br />

airlock) shower: with a chemical spr<strong>in</strong>kler<br />

recommended <strong>in</strong> case use is made<br />

of isolation suit fitted<br />

with positive air pressure)<br />

10 S<strong>in</strong>ks that can be operated not required recommended required required<br />

non-manually<br />

11 Coathooks or chang<strong>in</strong>g room for required required required required<br />

<strong>the</strong> protective cloth<strong>in</strong>g<br />

12 Tub<strong>in</strong>g fitted with a system that not required not required recommended required<br />

prevents backward flow of fluids<br />

13 Separate room for <strong>the</strong> stock<strong>in</strong>g of recommended required required required<br />

clean cages, feed and cag<strong>in</strong>g material<br />

14 Surfaces resistant to decontam<strong>in</strong>ants, required required required required<br />

impermeable and easy to clean (cages, benches) (cages, benches, (cages, benches, (cages, benches,<br />

floor) floor, walls, ceil<strong>in</strong>g) floor, walls, ceil<strong>in</strong>g)<br />

15 Facility for <strong>the</strong> wash<strong>in</strong>g of cages required required required required<br />

16 Automous electricity backup system not required not required recommended required<br />

17 Fire alarm (not tak<strong>in</strong>g <strong>in</strong>to account not required not required required required<br />

local fire regulations)<br />

18 System that enables communication not required not required required required (nonwith<br />

<strong>the</strong> outside world<br />

manual operation)<br />

VENTILATION<br />

19 Input airflowsystem separated from not required not required recommended required<br />

adjacent laboratories<br />

20 Extract airflowsystem separated from not required optional recommended required<br />

adjacent laboratories<br />

21 Input and extract airflowsystem not required optional required required<br />

<strong>in</strong>terconnected to prevent accidental<br />

overpressure<br />

22 Input and extract airflowsystem can be not required optional required required<br />

closed us<strong>in</strong>g valves<br />