3. Work<strong>in</strong>g practices and waste management<br />

Specifications<br />

Conta<strong>in</strong>ment level<br />

A1 A2 A3 A4<br />

34 Restricted access required required required (and control) required (and control)<br />

35 Notification on <strong>the</strong> door: “Biohazard” required, except <strong>the</strong> required required required<br />

symbol, coord<strong>in</strong>ates of person <strong>in</strong><br />

“Biohazard” symbol<br />

charge, conta<strong>in</strong>ment level, type of<br />

biological risk, list of persons who<br />

have access, criteria for admittance<br />

36 Animal hous<strong>in</strong>g to conta<strong>in</strong> its own not required recommended required required<br />

equipment<br />

37 Protective cloth<strong>in</strong>g that is specific required required required, + optionally required, complete<br />

for <strong>the</strong> conta<strong>in</strong>ment zone appropriate shoe change of cloth<strong>in</strong>g<br />

protection and footwear when<br />

enter<strong>in</strong>g or leav<strong>in</strong>g<br />

38 Decontam<strong>in</strong>ation of <strong>the</strong> protective not required not required required required<br />

cloth<strong>in</strong>g before it leaves <strong>the</strong><br />

conta<strong>in</strong>ment zone<br />

39 Gloves optional recommended required required<br />

40 Mouth mask not required optional optional required<br />

41 Face protection (eyes, mucosa) not required optional optional required<br />

42 Generation of aerosols m<strong>in</strong>imise m<strong>in</strong>imise prevent prevent<br />

43 Specific measures to prevent <strong>the</strong> spread not required recommended required required<br />

of aerosols (<strong>in</strong>clud<strong>in</strong>g appropriate<br />

equipment)<br />

44 Mechanical pipett<strong>in</strong>g required required required required<br />

45 No dr<strong>in</strong>k<strong>in</strong>g, eat<strong>in</strong>g or smok<strong>in</strong>g, no use required required required required<br />

of cosmetics, no manipulation of contacts,<br />

or <strong>the</strong> stock<strong>in</strong>g of consumables<br />

46 Register <strong>in</strong> which all activities are notified required required required required<br />

(transport of <strong>laboratory</strong> animals, <strong>in</strong>oculation<br />

of GMM’s etc....)<br />

47 Verification of control measures and required required required required<br />

protective equipment<br />

48 Notice on <strong>the</strong> use of decontam<strong>in</strong>ants required required required required<br />

49 Decontam<strong>in</strong>ants <strong>in</strong> <strong>the</strong> siphons not required recommended required required<br />

50 Instruction of <strong>the</strong> personnel required required required required<br />

51 Written <strong>in</strong>structions on <strong>the</strong> biosafety required required required required<br />

procedures<br />

52 Efficient vector control (eg. for rodents recommended required required required<br />

and <strong>in</strong>sects)<br />

53 Isolation of <strong>laboratory</strong> animals used required required required required<br />

for experimentation (separate room) (separate room) (separate room)<br />

54 In case of manipulation of zoopathogens, not required not required recommended, required,<br />

period dur<strong>in</strong>g which contact of <strong>the</strong> personnel period to be specified period to be specified<br />

with <strong>the</strong> host animals should be avoided <strong>in</strong> <strong>the</strong> authorisation <strong>in</strong> <strong>the</strong> authorisation<br />

WASTE MANAGEMENT<br />

55 Inactivation of biological waste and/or biological required required required required<br />

residues (contam<strong>in</strong>ated cadavers, faeces 9 ) us<strong>in</strong>g an<br />

appropriate and validated method before dump<strong>in</strong>g<br />

56 Inactivation of contam<strong>in</strong>ated material required required required required<br />

(glassware, cages, etc...) us<strong>in</strong>g an<br />

appropriate and validated method before<br />

reuse or destroy<strong>in</strong>g<br />

57 Inactivation of <strong>the</strong> effluents of s<strong>in</strong>ks and not required not required recommended required<br />

showers us<strong>in</strong>g an appropriate and validated<br />

method before dump<strong>in</strong>g<br />

9<br />

Faeces from transgenic animals does not have to be <strong>in</strong>activated<br />