Biosafety in the laboratory - VIB
Biosafety in the laboratory - VIB
Biosafety in the laboratory - VIB
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Specifications<br />
Conta<strong>in</strong>ment level<br />
A1 A2 A3 A4<br />
23 Negative airpressure <strong>in</strong> <strong>the</strong> not required optional required (control and required (control and<br />
controlled zone when compared alarm systems) alarm systems)<br />
to adjacent zones<br />
24 HEPA-filtration of <strong>the</strong> air 6 not required optional required (on <strong>the</strong> required (on <strong>the</strong> <strong>in</strong>ward<br />
extracted air airflow and double<br />
filtration on <strong>the</strong><br />
extraced air)<br />
25 System that allows chang<strong>in</strong>g of - - required required<br />
<strong>the</strong> filters without contam<strong>in</strong>ation<br />
of <strong>the</strong> environment<br />
26 HEPA-filtered air may be recirculated - - optional forbidden<br />
27 Specific measures to ventilate to such optional optional required 7 required<br />
an extent that contam<strong>in</strong>ation of <strong>the</strong> air<br />
is m<strong>in</strong>imized<br />
6<br />
In case of use of virus not reta<strong>in</strong>ed by HEPA filtration, special appropriate measures must be taken with regard to <strong>the</strong> extract air<br />
7<br />
Measures to be specified by <strong>the</strong> notifier and by <strong>the</strong> competent authorities<br />
2. Safety equipment<br />
Specifications<br />
Conta<strong>in</strong>ment level<br />
A1 A2 A3 A4<br />
28 Microbiological safety cab<strong>in</strong>et not required optional optional optional<br />
(class I or II) (class I or II) (class III, or class II with<br />
<strong>the</strong> use of an isolation<br />
suit fitted with<br />
overpressure)<br />
29 Animals <strong>in</strong> cages or equivalent optional optional optional optional<br />
isolation <strong>in</strong>stallations<br />
30 Cages fitted with a HEPA filter not required optional required required<br />
31 Autoclave on site <strong>in</strong> <strong>the</strong> build<strong>in</strong>g <strong>in</strong> <strong>the</strong> animalarium or <strong>in</strong> <strong>the</strong> animalarium<br />
an adjacent room 8<br />
32 Double-ended autoclave not required not required recommended required<br />
33 Fumigationsystem or not required recommended required required<br />
decontam<strong>in</strong>ation immersion bath<br />
8<br />
Transfer of material to an autoclave situated outside <strong>the</strong> <strong>laboratory</strong> should occur accord<strong>in</strong>g to a validated method that guarantees an<br />
equivalent protection level.<br />
Conta<strong>in</strong>ment requirements 51