FS2004 Users Manual - FuturePlus Systems
FS2004 Users Manual - FuturePlus Systems
FS2004 Users Manual - FuturePlus Systems
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Environmental<br />
Temperature<br />
Altitude<br />
Operating:0 to 55 degrees C (+32 to +131 degrees F)<br />
Non operating:-40 to +75 degrees C (-40 to +167 degrees F)<br />
Operating: 4,6000m (15,000 ft)<br />
Non operating: 15,3000m (50,000 ft)<br />
Humidity<br />
Testing and<br />
Troubleshooting<br />
Servicing<br />
Up to 90% non condensing. Avoid sudden, extreme temperature<br />
changes which would cause condensation on the <strong>FS2004</strong><br />
module.<br />
There are no automatic performance tests or adjustments for the<br />
<strong>FS2004</strong> module. If a failure is suspected in the <strong>FS2004</strong> module<br />
contact the factory or your <strong>FuturePlus</strong> <strong>Systems</strong> authorized<br />
distributor.<br />
The repair strategy for the <strong>FS2004</strong> is module replacement.<br />
However, if parts of the <strong>FS2004</strong> module are damaged or lost<br />
contact the factory for a list of replacement parts.<br />
46