Power Failure - Power failure interrupt (low line voltage)<br />

Enc Chip Bad - Encoder chip bad<br />

Interrupt Flt - Timer/interrupt fault<br />

1kHZ Missing - Clock generation logic failure (1 kHz signal missing)<br />

Scal Cmp Lrge - Exceeding maximum allowed rotary scales compensation.<br />

HRT210SC only<br />

0 Margin Small - (Zero margin too small) Distance between the home switch<br />

and the final motor position, after seeking home, is either less than 1/8 or greater<br />

than 7/8 of a motor revolution. This alarm occurs while homing the rotary table.<br />

Parameter 45, for the A-axis or Parameter 91 for the B-axis must be set properly.<br />

Use the default value (0) for the axis parameter (45 or 91) and add 1/2 of a motor<br />

revolution. 1/2 motor revolution is calculated by taking the value in Parameter 28<br />

for the A-axis, or Parameter 74 for the B-axis and dividing by 2. Enter this value for<br />

parameter 45 or 91 and re-home the rotary table.<br />

Servo Off Codes<br />

At any time the servo (motor) is turned off,a reason code is displayed along with<br />

the following codes. An “A” or “B” may precede the code for TRT units. This is the<br />

reference to the axis that caused the fault.<br />

Por On - Power just applied (or failed previously)<br />

Servo Err Lrge - Servo following error too large (see Parameter 22 or 68)<br />

E-Stop - Emergency stop<br />

Servo Overload - Software fuse. Unit was turned off due to overload condition<br />

(see Parameter 23 or 69)<br />

RS-232 Problem - Remote RS-232 commanded off<br />

Encoder Fault - Z channel fault (bad encoder or cable)<br />

Scale Z Fault - Rotary scale Z channel fault (bad rotary scale encoder or cable)<br />

HRT210SC only<br />

Z Encod Missing - Z channel missing (bad encoder or cable)<br />

Scale Z Missing - Rotary scale Z channel missing (bad rotary scale encoder or<br />

cable) HRT210SC only<br />

Regen Overheat - High line voltage<br />

Cable Fault - Break detected in encoder cable wiring<br />

Scale Cable - Break detected in rotary scale cable wiring (HRT210SC only)<br />

Pwr Up Phase Er - Power up phase error<br />

Drive Fault - An overcurrent or drive fault.<br />

Enc Trans Flt - Encoder transition fault had been detected.<br />

Indr Not Up - Platter not fully up (HRT320FB only). Can be caused by low air pressure.<br />