Service and maintenance<br />
8.2 Checking and changing lubricants<br />
8.2.2 Checking the oil level<br />
CAUTION<br />
The volume of gear oils changes with temperature.<br />
If the temperature rises, the volume increases. Where temperature differences and filling<br />
quantities are significant, the increase can amount to several liters.<br />
The oil level must there<strong>for</strong>e be checked while still slightly warm, approximately 30 minutes<br />
after switching off the drive unit.<br />
<br />
Figure 8-1<br />
Oil level in the gearbox housing<br />
Procedure<br />
1. Switch off the power supply to the drive unit.<br />
2. Unscrew the oil level screw, see Designs (Page 63).<br />
3. Check the oil level 1.<br />
4. Rectify the oil level 1 if necessary and check it again.<br />
5. Check the condition of the sealing ring on the sealing element and replace the sealing<br />
ring if necessary.<br />
6. Seal the gearbox with the sealing element.<br />
You have now checked the oil level in the gearbox housing.<br />
BA 2515<br />