Functional characteristics<br />

<strong>Operating</strong> concepts<br />

5.2.10 Shielding gas setting<br />

5.2.10.1 Gas test<br />

<strong>Operating</strong> Action Result<br />

element<br />

x x<br />

Press the "Select welding parameter" button until the "activArc" LED<br />

flashes.<br />

5 sec. Press the "Select welding parameter" button and hold for approx. 5 sec.<br />

The gas pre-flow time LED (TIG) sec will come on,<br />

shielding gas flows for approx. 20 sec.<br />

5.2.11 <strong>Welding</strong> torch (operating variants)<br />

Different torch versions can be used with this machine.<br />

Functions on the operating elements, such as torch triggers (TT), rockers or potentiometers, can be<br />

modified individually via torch modes.<br />

Explanation of symbols for operating elements:<br />

Symbol<br />

Description<br />

BRT 1 Press torch trigger<br />

BRT 1 Tap torch trigger *<br />

BRT 2<br />

Tap * and press torch trigger<br />

5.2.11.1 Tap torch trigger (tapping function)<br />

NOTE<br />

Pressing the torch trigger briefly to change a function, e.g. changing over from main to<br />

secondary current.<br />

The function is used in torch modes 1-6 (factory setting). The function is deactivated in<br />

torch modes 11-16 (for more in-depth information, see Torch mode setting chapter).<br />