Commissioning<br />

MMA welding<br />

6.8 MMA welding<br />

CAUTION<br />

Risk of being crushed or burnt.<br />

When replacing spent or new stick electrodes<br />

• Switch off machine at the main switch<br />

• Wear appropriate safety gloves<br />

• Use insulated tongs to remove spent stick electrodes or to move welded workpieces and<br />

• Always put the electrode holder down on an insulated surface.<br />

6.8.1 Connecting the electrode holder and workpiece lead<br />

2<br />

3 1<br />

Figure 6-5<br />

Item Symbol Description 0<br />

1 Connection socket, “-” welding current<br />

Electrode holder connection<br />

2 Connection socket, “+” welding current<br />

Connection for workpiece lead<br />

3 G¼” connecting nipple, “-” welding current<br />

Shielding gas connection (with yellow insulating cap) for TIG welding torch<br />

CAUTION<br />

Shielding gas connection!<br />

During MMA welding open circuit voltage is applied at the shielding gas connection<br />

(G¼" connecting nipple).<br />

• Place yellow insulating cap on the G¼" connection nipple (protects against electrical voltage<br />

and dirt).<br />

64 Item No.: 099-000097-<strong>EWM</strong>01