Functional characteristics<br />

Remote control<br />

5.4.5 Foot-operated remote control RTF 1<br />

Functions<br />

• Infinitely adjustable welding current (0% to 100%) depending on the preselected<br />

main current on the welding machine.<br />

• Start/stop welding operation (TIG)<br />

ActivArc welding is not possible in combination with the RTF 1 foot-operated remote control.<br />

I<br />

FFr>off<br />

FFr>on<br />

I start<br />

I end<br />

t<br />

Figure 5-14<br />

Symbol<br />

Meaning<br />

Actuate foot-operated remote control (start welding process)<br />

Operate foot-operated remote control (set welding current according to application)<br />

Release foot-operated remote control (end welding process)<br />

FFr<br />

RTF ramp function<br />

on <strong>Welding</strong> current runs in a ramp function at the specified main current<br />

off <strong>Welding</strong> current goes immediately to the specified main current<br />

NOTE<br />

The RTF ramp function can be switched on and off in the machine control sub-menu (see<br />

"Advanced settings > ramp function RTF" chapter).<br />

Item No.: 099-000097-<strong>EWM</strong>01 47