Functional characteristics<br />
Remote control<br />
5.4.5 Foot-operated remote control RTF 1<br />
Functions<br />
• Infinitely adjustable welding current (0% to 100%) depending on the preselected<br />
main current on the welding machine.<br />
• Start/stop welding operation (TIG)<br />
ActivArc welding is not possible in combination with the RTF 1 foot-operated remote control.<br />
I<br />
FFr>off<br />
FFr>on<br />
I start<br />
I end<br />
t<br />
Figure 5-14<br />
Symbol<br />
Meaning<br />
Actuate foot-operated remote control (start welding process)<br />
Operate foot-operated remote control (set welding current according to application)<br />
Release foot-operated remote control (end welding process)<br />
FFr<br />
RTF ramp function<br />
on <strong>Welding</strong> current runs in a ramp function at the specified main current<br />
off <strong>Welding</strong> current goes immediately to the specified main current<br />
NOTE<br />
The RTF ramp function can be switched on and off in the machine control sub-menu (see<br />
"Advanced settings > ramp function RTF" chapter).<br />
Item No.: 099-000097-<strong>EWM</strong>01 47