9.4 General operating problems<br />

<strong>Operating</strong> problems, causes and remedies<br />

General operating problems<br />

Problem<br />

Possible cause > remedy<br />

Machine control without displaying the signal • Phase failure > check mains connection (fuses)<br />

lights after switching on<br />

no welding performance • Phase failure > check mains connection (fuses)<br />

various parameters cannot be set • Entry level is blocked > disable access lock (see<br />

chapter entitled "key switch", if available)<br />

9.4.1 Interface for mechanised welding<br />

WARNING<br />

No function of the external shut-down devices (emergency stop switch)!<br />

If the emergency stop circuit has been realised using an external shut-down device via<br />

the interface for mechanised welding, the device must be set for this setup. If this is not<br />

observed, the power source will ignore the external shut-down devices and will not shut<br />

down!<br />

• Disconnect jumper 1 on PCB T320/1 (TETRIX) or M320/1 (PHOENIX / alpha Q)!<br />

Item No.: 099-000097-<strong>EWM</strong>01 77